Owner's manual

DS2711/DS2712: Loose Cell NiMH Charger
3 of 13
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Threshold Voltage,
Thermistor - Min
V
THM-MIN
(Notes 1, 4, 6)
V
DD
x
0.73
V
Threshold Voltage,
Thermistor - Max
V
THM-MAX
(Notes 1, 4, 6) 0.30
V
DD
x
0.33
0.36 V
Threshold Voltage,
Thermistor - Stop
V
THM-STOP
(Notes 1, 4, 6)
V
DD
x
0.29
V
Threshold Current, TMR
Pin Suspend
I
TMR-SUS
0.1 0.5
mA
Presence Test Current,
VP1, VP2
I
PTST
Parallel: V
DD
4.0V,
Series: V
DD
4.5V
10 15
mA
Reverse Leakage
Current, VP1, VP2
I
LKGR
V
DD
= 0V, VP1 = 1.5V,
VP2 = 3.0V
2
mA
125 mV
Current-Sense Reference
Voltage
V
IREF
(Note 1, 4, 7)
-6% +6% %
Gain, Current-Sense
Error Amp
G
M
DS2711 (Note 8) 0.9 1.5
W
-1
Gain, Current-Sense
Comparator
G
M
DS2712 (Note 8) 10
W
-1
Propagation Time,
Current-Sense
Comparator
t
PDLY
DS2712, 2mV
over/underdrive
0.25
ms
Hysteresis, Current-
Sense Comparator
V
HYS-COMP
DS2712 22 24 26 mV
ELECTRICAL CHARACTERISTICS: TIMING
(4.0V £ V
DD
£ 5.5V, T
A
= -20°C to +70°C, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Internal Timebase Period t
BASE
0.96 s
Internal Timebase
Accuracy
-10 +10 %
Duty Factor, Series Fast
Charge
CC1 0.969
Duty Factor, Series
Precharge/Top-Off
CC1 0.250
Duty Factor, Parallel Fast
Charge
CC1, CC2 0.484
Duty Factor, Parallel
Precharge/Top-Off
CC1, CC2 0.125
Duty Factor, Maintenance
Charge
CC1, CC2 0.0156
Cell Test Interval t
CTST
31 s
Precharge Time-Out t
PCHG
V
CELL
< V
BAT-MIN
34 minutes
Fast-Charge Termination
Hold-Off Period
t
THO
4 minutes
Fast-Charge Flat Voltage
Time-Out
t
FLAT
V
CELL
not increasing 16 minutes
Charge Timer Period t
CTMR
R
TMR
= 100kW
1.0 h
Charge Timer Accuracy
R
TMR
= 100kW
-5 +5 %
Charge Timer Range t
CTMR-RANGE
0.5 10 h