User guide

DS1875
PON Triplexer and SFP Controller
44 ______________________________________________________________________________________
FACTORY DEFAULT 0000h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
0Ah, 0Eh,
12h, 16h,
1Ah, 1Eh,
22h, 26h,
2Ah, 2Eh
2
15
2
14
2
13
2
12
2
11
2
10
2
9
2
8
0Bh, 0Fh,
13h, 17h,
1Bh, 1Fh,
23h, 27h,
2Bh, 2Fh
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT 7 BIT 0
Voltage measurement updates below this unsigned threshold set its corresponding alarm or warning bit.
Voltage measurements equal to or above this threshold clear its alarm or warning bit.
Lower Memory, Register 0Ah to 0Bh: V
CC
ALARM LO
Lower Memory, Register 0Eh to 0Fh: V
CC
WARN LO
Lower Memory, Register 12h to 13h: MON1 ALARM LO
Lower Memory, Register 16h to 17h: MON1 WARN LO
Lower Memory, Register 1Ah to 1Bh: MON2 ALARM LO
Lower Memory, Register 1Eh to 1Fh: MON2 WARN LO
Lower Memory, Register 22h to 23h: MON3 ALARM LO
Lower Memory, Register 26h to 27h: MON3 WARN LO
Lower Memory, Register 2Ah to 2Bh: MON4 ALARM LO
Lower Memory, Register 2Eh to 2Fh: MON4 WARN LO