Owner's manual
Note 1: All voltages are referenced to ground. Current into the IC is positive, and current out of the IC is negative.
Note 2: Inputs are at supply rail. Outputs are not loaded.
Note 3: This parameter is guaranteed by design.
Note 4: Full-scale is user programmable.
Note 5: The DACs are the bias and modulation DACs found in the MAX3798/MAX3799 that are controlled by the DS1874.
Note 6: The DS1874 is configured with TXDOUT connected to the MAX3798/MAX3799 DISABLE input.
Note 7: This includes writing to the modulation DAC and the initial step written to the bias DAC.
Note 8: A temperature conversion is completed and the modulation register value is recalled from the LUT and V
CC
has been
measured to be above V
CC
LO alarm.
Note 9: The timing is determined by the choice of the update rate setting (see Table 02h, Register 88h).
Note 10: This specification is the time it takes from MON3 voltage falling below the LLOS trip threshold to LOSOUT asserted high.
Note 11: This specification is the time it takes from MON3 voltage rising above the HLOS trip threshold to LOSOUT asserted low.
Note 12: Assuming an appropriate initial step is programmed that would cause the power to exceed the APC set point within four
steps, the bias current will be within 3% within the time specified by the binary search time. See the
BIAS and MODULA-
TION Control During Power-Up
section.
Note 13: I
2
C interface timing shown is for fast mode (400kHz). This device is also backward compatible with I
2
C standard mode
timing.
Note 14: C
B
—the total capacitance of one bus line in pF.
Note 15: EEPROM write begins after a STOP condition occurs.
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
SCL Clock Frequency f
SCL
(Note 13) 0 400 kHz
Clock Pulse-Width Low t
LOW
1.3 μs
Clock Pulse-Width High t
HIGH
0.6 μs
Bus-Free Time Between STOP and START
Condition
t
BUF
1.3 μs
START Hold Time t
HD:STA
0.6 μs
START Setup Time t
SU:STA
0.6 μs
Data Out Hold Time t
HD:DAT
0 0.9 μs
Data In Setup Time t
SU:DAT
100 ns
Rise Time of Both SDA and SCL Signals t
R
(Note 14) 20 + 0.1C
B
300 ns
Fall Time of Both SDA and SCL Signals t
F
(Note 14) 20 + 0.1C
B
300 ns
STOP Setup Time t
SU:STO
0.6 μs
EEPROM Write Time t
W
(Note 15) 20 ms
Capacitive Load for Each Bus Line C
B
400 pF
DS1874
SFP+ Controller with Digital LDD Interface
8 _______________________________________________________________________________________
NONVOLATILE MEMORY CHARACTERISTICS
(V
CC
= +2.85V to +3.9V, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
At +25°C 200,000
EEPROM Write Cycles
At +85°C 50,000
I
2
C AC ELECTRICAL CHARACTERISTICS
(V
CC
= +2.85V to +3.9V, T
A
= -40°C to +95°C, timing referenced to V
IL(MAX)
and V
IH(MIN)
, unless otherwise noted. See Figure 17.)