Owner's manual

DS1874
SFP+ Controller with Digital LDD Interface
______________________________________________________________________________________ 79
Table 02h, Register EAh: SETCML
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)
WRITE ACCESS PW2 or (PW1 and RWTBL246)
MEMORY TYPE Nonvolatile (SEE)
EAh 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT 7 BIT 0
MAX3798/MAX3799 register. After either V
CC
exceeds POA (after a POR event), the MAX3798/MAX3799 TX_POR
bit is set high (visible in 3W TXSTAT1, Bit 7) or on a rising edge of TXD, this value is written to the MAX3798/
MAX3799 through the 3-wire interface.
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)
WRITE ACCESS PW2 or (PW1 and RWTBL246)
MEMORY TYPE Nonvolatile (SEE)
EBh 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT 7 BIT 0
MAX3798/MAX3799 register. After either V
CC
exceeds POA (after a POR event), the MAX3798/MAX3799 TX_POR
bit is set high (visible in 3W TXSTAT1, Bit 7) or on a rising edge of TXD, this value is written to the MAX3798/
MAX3799 through the 3-wire interface.
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)
WRITE ACCESS PW2 or (PW1 and RWTBL246)
MEMORY TYPE Nonvolatile (SEE)
ECh 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT 7 BIT 0
MAX3798/MAX3799 register. After either V
CC
exceeds POA (after a POR event), the MAX3798/MAX3799 TX_POR
bit is set high (visible in 3W TXSTAT1, Bit 7) or on a rising edge of TXD, this value is written to the MAX3798/
MAX3799 through the 3-wire interface.
Table 02h, Register EBh: SETLOS
Table 02h, Register ECh: TXCTRL