78 ______________________________________________________________________________________
Table 02h, Register E8h: RXCTRL1
FACTORY DEFAULT 00h
READ ACCESS N/A
WRITE ACCESS N/A
MEMORY TYPE None
These registers do not exist.
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)
WRITE ACCESS PW2 or (PW1 and RWTBL246)
MEMORY TYPE Nonvolatile (SEE)
E8h 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT 7 BIT 0
MAX3798/MAX3799 register. After either V
CC
exceeds POA (after a POR event), the MAX3798/MAX3799 TX_POR
bit is set high (visible in 3W TXSTAT1, Bit 7) or on a rising edge of TXD, this value is written to the MAX3798/
MAX3799 through the 3-wire interface.
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)
WRITE ACCESS PW2 or (PW1 and RWTBL246)
MEMORY TYPE Nonvolatile (SEE)
E9h 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT 7 BIT 0
MAX3798/MAX3799 register. After either V
CC
exceeds POA (after a POR event), the MAX3798/MAX3799 TX_POR
bit is set high (visible in 3W TXSTAT1, Bit 7) or on a rising edge of TXD, this value is written to the MAX3798/
MAX3799 through the 3-wire interface.
Table 02h, Register D8h–E7h: EMPTY
Table 02h, Register E9h: RXCTRL2