6.4 Serial Communication
The Camera Link interface provides two LVDS signal pairs for the communication between the
camera and the frame grabber. This is an asynchronous serial communication based on RS-232
protocol.
The configuration of the serial line is:
• Full duplex/without handshaking
• 8-bit data, no parity bit, 1 stop bit
• 9600 bauds at power up, then programmable up to 115200 bauds (see register
Communication Speed Multiplieur @ 001H, Internal Register Mapping on page 16.
6.4.1 Internal Register
Table 6-5. Camera Link Serial Communication Description
Signal Name I/O Type Description
SerTFG O RS644
Differential pair for serial communication
to the frame grabber
SerTC I RS644
Differential pair for serial communication
from the frame grabber
Table 6-6. Internal Register Mapping
Start Addr
(Hex) Size (Dec)
End
Addr (Hex)
Access Type
Processing Internal Task
Factory
Settings Description
000 1 RO RO
Synchronization register for serial
communication (value 00)
001 1 RW - 1
Communication speed multiplier (9600 -
115,2K): volatile register 1, 2, 3, 4, 6, 8, 12
040 51 RO - Hardware identifier
080 8 RO - Firmware identifier
0C0 51 RW - User identifier
100 4 RW RW Status (ref. Camera Status Management)
104 4 WO -
Lock/Unlock mode: advanced user/user
1: Lock advanced user mode
(into user mode)
Unlock key value: unlock user
108 1 RO -
Privilege level
1: Advanced user mode
2: User mode
109 1 WO -
Current configuration save in Eeprom
1: User settings (allowed only for advanced
user mode)
2 to 4: User settings