User Manual
16
4856E–AUTO–07/07
ATA6823 [Preliminary]
7. Thermal Resistance
Parameters Symbol Value Unit
Thermal resistance junction to heat slug R
thjc
<5 K/W
Thermal resistance junction to ambient when heat
slug is soldered to PCB
R
thja
25 K/W
8. Operating Range
The operating conditions define the limits for functional operation and parametric characteristics of the device. Functionality outside these
limits is not implied unless otherwise stated explicitly.
Parameters Symbol Min Max Unit
Operating supply voltage
(1)
V
VBAT1
718V
Operating supply voltage
(2)
V
VBAT2
6< 7V
Operating supply voltage
(3)
V
VBAT3
3< 6V
Operating supply voltage
(4)
V
VBAT4
0< 3V
Operating supply voltage
(5)
V
VBAT5
> 20 40 V
Ambient temperature range under bias T
a
–40 +125 °C
Normal functionality T
a
–40 +125 °C
Normal functionality, overtemperature warning T
a
150 165 °C
Drivers for H1, H2, L1, L2, and LIN are switched
OFF, VCC regulator is OFF
T
a
165 180 °C
Note: 1. Full functionality
2. H-bridge drivers may be switched off (undervoltage detection)
3. H-bridge drivers are switched off, 5V/3.3V regulator with reduced parameters, RESET works correctly
4. H-bridge drivers are switched off, 5V regulator not working, RESET not correct
5. H-bridge drivers are switched off