Manual
37
4596A–RKE–05/06
ATA5745/ATA5746 [Preliminary]
15. Electrical Characteristics: 5V Application
All parameters refer to GND and are valid for T
amb
= –40°C to +105°C, V
VS3V_AVCC
= V
VS5V
= 2.7V to 3.3V, and V
VS5V
= 4.5V to 5.5V.
Typical values are given at V
VS3V_AVCC
= V
VS5V
= 3V, T
amb
= 25°C, and f
RF
= 433.92 MHz unless otherwise specified. Details about current
consumption, timing, and digital pin properties can be found in the specific sections of the “Electrical Characteristics”.
No. Parameters Test Conditions Pin Symbol Min. Typ. Max. Unit Type*
85V Application
8.1
Supply current in OFF
mode
V
VS5V
=5V
CLK_OUT disabled
10 I
SOFF
2µAA
8.2
Supported voltage
range
5V application 10 V
VS5V
4.5 5.5 V A
8.3
Current in Standby
mode (XTO is
running)
V
VS5V
≤ 5V
external load C on pin
CLK_OUT = 12 pF
CLK enabled
(division ratio 3)
CLK enabled
(division ratio 6)
CLK enabled
(division ratio 12)
CLK disabled
10 I
Standby
700
490
370
50
µA
C
C
C
A
8.4
Current during
T
Startup_PLL
V
VS5V
=5V
CLK disabled
10 I
Startup_PLL
4.7 mA C
8.5
Current in Active
mode ASK
V
VS5V
=5V
CLK disabled
SENSE_CTRL = 0
10 I
Active
6.7 mA A
8.6
Current in Active
mode FSK
V
VS5V
=5V
CLK disabled
SENSE_CTRL = 0
10 I
Active
6.9 mA A
*) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter