Manual

158
AT89C5131
4136AUSB03/03
Table 105. AC Parameters for a Fix Clock (F = 40 MHz)
Table 106. AC Parameters for a Variable Clock
Symbol Min Max Units
T25 ns
T
LHLL
40 ns
T
AVLL
10 ns
T
LLAX
10 ns
T
LLIV
70 ns
T
LLPL
15 ns
T
PLPH
55 ns
T
PLIV
35 ns
T
PXIX
0ns
T
PXIZ
18 ns
T
AVIV
85 ns
T
PLAZ
10 ns
Symbol Type
Standard
Clock X2 Clock X Parameter Units
T
LHLL
Min 2 T - x T - x 10 ns
T
AVLL
Min T - x 0.5 T - x 15 ns
T
LLAX
Min T - x 0.5 T - x 15 ns
T
LLIV
Max 4 T - x 2 T - x 30 ns
T
LLPL
Min T - x 0.5 T - x 10 ns
T
PLPH
Min 3 T - x 1.5 T - x 20 ns
T
PLIV
Max 3 T - x 1.5 T - x 40 ns
T
PXIX
Min x x 0 ns
T
PXIZ
Max T - x 0.5 T - x 7 ns
T
AVIV
Max 5 T - x 2.5 T - x 40 ns
T
PLAZ
Max x x 10 ns