Table 11. 3-wire Serial Interface Data Setting Description
Setting for Address:
000 D15 D14 D13 D12 D11 D10 D9
(1)
D8 D7 D6 D5 D4 D3 D2 D1 D0
Full standby mode XXXXXX 0 XXXXXXX11
Standby channel I
(2)
XXXXXX 0 XXXXXXX01
Standby channel Q
(3)
XXXXXX 0 XXXXXXX10
No standby mode XXXXXX 0 XXXXXXX00
Binary output mode XXXXXX 0 XXXXXX1XX
Gray output mode XXXXXX 0 XXXXXX0XX
DMUX 1:2 mode XXXXXX 0 XXXXX1XXX
DMUX 1:1 mode XXXXXX 0 XXXXX0XXX
Analog selection mode
Input I
→ ADC I
Input Q → ADC Q
XXXXXX 0 XXX11XXXX
Analog selection mode
Input I
→ ADC I
Input I → ADC Q
XXXXXX 0 XXX10XXXX
Analog selection mode
Input Q
→ ADC I
Input Q → ADC Q
XXXXXX 0 XXX0XXXXX
Clock Selection mode
CLKI
→ ADC I
CLKQ → ADC Q
XXXXXX 0 X11XXXXXX
Clock selection mode
CLKI
→ ADC I
CLKI → ADC Q
XXXXXX 0 X10XXXXXX
Clock selection mode
CLKI
→ ADC I
CLKIN → ADC Q
XXXXXX 0 X0XXXXXXX
Decimation OFF modeXXXXXX 0 0XXXXXXXX
Decimation ON mode XXXXXX 0 1XXXXXXXX
Keep last calibration
calculated value
(4)
No calibration phase
XXXX01 0 XXXXXXXXX
No calibration phase
(5)
No calibration value
XXXX00 0 XXXXXXXXX
Start a new calibration
phase
XXXX11 0 XXXXXXXXX