Owner manual

74
AT76C551
1612D08/01
Electrical Specifications
Recommended Operating Conditions
Table 14 shows the range for which Atmel library cells have been characterized. Operation of a device outside this range
may result in the device failing to meet some of its specification.
Absolute Maximum Ratings
Operation of a device outside of the range givein in Table 15 may cause permanent damage to the device and/or affect
reliability.
Table 14. Recommended Operating Conditions
Symbol Parameter Conditions Min Typ Max Unit
V
DD3
DC Supply Voltage Core and Standard I/Os 3.0 3.3 3.6 V
V
I
DC Input Voltage 0 VDD V
V
O
DC Output Voltage 0 VDD V
TEMP Operating Free Air Temperature Range Industrial -40 +85 °C
Table 15. Absolute Maximum Ratings
Symbol Parameter Conditions Min Max Unit
V
DD3
DC Supply Voltage Core and Standard I/Os -0.3 3.6 V
V
I
DC Input Voltage -0.3 VDD+0.3 V
V
O
DC Output Voltage -0.3 VDD+0.3 V
TEMP Operating Free Air Temperature Range Industrial -40 +85 °C
TSG Storage Temperature -60 +150 °C