AIC Source Mode Register
Register Name: AIC_SMR0..AIC_SMR31
Access Type: Read/write
Reset Value: 0
PRIOR: Priority Level
Programs the priority level for all sources except source 0 (FIQ).
The priority level can be between 0 (lowest) and 7 (highest).
The priority level is not used for the FIQ in the SMR0.
SRCTYPE: Interrupt Source Type
Programs the input to be positive- or negative-edge triggered or positive- or negative-level sensitive.
The active level or edge is not programmable for the internal sources.
AIC Interrupt Vector Register
Register Name: AIC_IVR
Access Type: Read-only
Reset Value: 0
PRIOR
Interrupt priority
IRQID
Active interrupt number. Used to select required service routine.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
SRCTYPE –– PRIOR
SRCTYPE Internal Sources External Sources
00
Level-sensitive Low-level sensitive
01
Edge-triggered Negative-edge triggered
10
Level-sensitive High-level sensitive
11
Edge-triggered Positive-edge triggered
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
PRIOR IRQID