Manual

AT75C310
114
MODF: Mode Fault Interrupt Disable
0 = No effect.
1 = Disables the Mode Fault Interrupt.
OVRES: Overrun Error Interrupt Disable
0 = No effect.
1 = Disables the Overrun Error Interrupt.
SPI Interrupt Mask Register
Register Name: SP_IMR
Access Type: Read-only
RDRF: Receive Data Register Full Interrupt Mask
0 = Receive Data Register Full Interrupt is disabled.
1 = Receive Data Register Full Interrupt is enabled.
TDRE: Transmit Data Register Empty Interrupt Mask
0 = Transmit Data Register Empty Interrupt is disabled.
1 = Transmit Data Register Empty Interrupt is enabled.
MODF: Mode Fault Interrupt Mask
0 = Mode Fault Interrupt is disabled.
1 = Mode Fault Interrupt is enabled.
OVRES: Overrun Error Interrupt Mask
0 = Overrun Error Interrupt is disabled.
1 = Overrun Error Interrupt is enabled.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
––––OVRES MODF TDRE RDRF