SPI Interrupt Enable Register
Register Name: SP_IER
Access Type: Write-only
• RDRF: Receive Data Register Full Interrupt Enable
0 = No effect.
1 = Enables the Receiver Data Register Full Interrupt.
• TDRE: SPI Transmit Data Register Empty Interrupt Enable
0 = No effect.
1 = Enables the Transmit Data Register Empty Interrupt.
• MODF: Mode Fault Error Interrupt Enable
0 = No effect.
1 = Enables the Mode Fault Interrupt.
• OVRES: Overrun Error Interrupt Enable
0 = No effect.
1 = Enables the Overrun Error Interrupt.
SPI Interrupt Disable Register
Register Name: SP_IDR
Access Type: Write-only
• RDRF: Receive Data Register Full Interrupt Disable
0 = No effect.
1 = Disables the Receiver Data Register Full Interrupt.
• TDRE: Transmit Data Register Empty Interrupt Disable
0 = No effect.
1 = Disables the Transmit Data Register Empty Interrupt.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
––––OVRES MODF TDRE RDRF
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
––––OVRES MODF TDRE RDRF