Owner's manual

AT27LV520
4
Note: 1. V
CC
standby current will be slightly higher with ALE, Ai, and ADi at TTL levels.
DC and AC Operating Conditions for Read Operation
AT27LV520-70 AT27LV520-90
Operating Temp. (Case)
Com. 0°C - 70°C0°C - 70°C
Ind. -40°C - +85°C-40°C - +85°C
V
CC
Supply
3.0V to 3.6V 3.0V to 3.6V
5V ±=10% 5V ±=10%
DC and Operating Characteristics for Read Operation
Symbol Parameter Condition Min Max Units
V
CC
= 3.0V to 3.6V
I
LI
Input Load Current V
IN
= 0V to V
CC
±A
I
LO
Output Leakage Current V
OUT
= 0V to V
CC
±A
I
SB
(1)
V
CC
Standby Current ALE = V
CC
± 0.3V; Ai, ADi = GND/V
CC
± 0.3V 20 µA
I
CC
V
CC
Active Current f = 5 MHz, I
OUT
= 0 mA, ALE = V
IL
8mA
V
IL
Input Low Voltage -0.6 0.8 V
V
IH
Input High Voltage 2.0 V
CC
+ 0.5 V
V
OL
Output Low Voltage I
OL
= 2.0 mA 0.4 V
V
OH
Output High Voltage I
OH
= -2.0 mA 2.4 V
V
CC
= 4.5V to 5.5V
I
LI
Input Load Current V
IN
= 0V to V
CC
±A
I
LO
Output Leakage Current V
OUT
= 0V to V
CC
±A
I
SB
(1)
V
CC
Standby Current ALE = V
CC
± 0.3V; Ai, ADi = GND/V
CC
± 0.3V 100 µA
I
CC
V
CC
Active Current f = 5 MHz, I
OUT
= 0 mA, ALE = V
IL
20 mA
V
IL
Input Low Voltage -0.6 0.8 V
V
IH
Input High Voltage 2.0 V
CC
+ 0.5 V
V
OL
Output Low Voltage I
OL
= 2.1 mA 0.4 V
V
OH
Output High Voltage I
OH
= -400 µA 2.4