Manual

Integrated Circuits Inc. aP89021/010
Ver 2.0 Dec 6, 2006
11
Key Trigger Mode
Up to 12 Voice Groups can be triggered by S1 to S4.
Voice Group
S1 S2 S3 S4
1 HIGH NC NC NC
2 NC HIGH NC NC
3 NC NC HIGH NC
4 NC NC NC HIGH
5 HIGH HIGH NC NC
6 NC HIGH HIGH NC
7 NC NC HIGH HIGH
8 HIGH NC NC HIGH
9 HIGH HIGH HIGH NC
10 NC HIGH HIGH HIGH
11 HIGH NC HIGH HIGH
12 HIGH HIGH NC HIGH
CPU Trigger Mode
Up to 12 Voice Groups can be triggered by supplying address to [S4:S1] with SBT as strobe signal.
Voice Group
S4 S3 S2 S1
1 0 0 0 0
2 0 0 0 1
3 0 0 1 0
4 0 0 1 1
5 0 1 0 0
6 0 1 0 1
7 0 1 1 0
8 0 1 1 1
9 1 0 0 0
10 1 0 0 1
11 1 0 1 0
12 1 0 1 1