First Flush w/ Catch-All Tee and Electronic Valve Installation and Specification Guide PRODUCT DETAILS The revolutionary First Flush w/ Catch-All Tee and Electronic Valve diverts more contaminants and gives you greater control over water volume. The Electronic Release Valve allows you to precisely set how often you want to divert water so you can optimise the quality and quantity of water you catch in your tank.
Installation WHAT’S IN THE BOX? TOOLS/MATERIALS YOU MAY REQUIRE 100mm/4” Catch-All Tee 100mm pipe (for diversion chamber) Ball seat Tape measure 100mm/4” socket reducer Marker pen 100mm/4” pipe wall brackets x 2 Saw Sealing ball Solvent weld glue Transparent, Rapid Release Exit Funnel Screws Electronic Release Valve Drill or screwdriver Primary Filter Screen 2 new 1.
using tee in vertical positions, always ensure the arrow is pointed ‘up’ (see Figure 1a/1b).) 4 - Orient the ball seat so it will fit inside the Catch-All Tee socket that will attach to your diversion chamber, then apply solvent weld glue and press it hard up inside the socket. 5 - If you are attaching your First Flush w/ Catch-All Tee and Electronic Valve to existing 90mm downpipes, install both 100x90mm socket in pipe reducer into the remaining Catch-All Tee sockets.
2c - Attach the Electronic Release valve by first installing the 25mm x 20mm (1” x 3/4”) reducing adaptor and washer to the 25mm (1”) thread of the screw cap. Washer 2c - Remove the union from the valve and attach to the reducing adaptor with 20mm (3/4”) washer in place. Washer 2e - Attach the valve at the union and orientate dial for easy access. O-ring 2f - Remove the waterproof cover from the Electronic Release Valve. rainharvesting.
2g - Ensure the reset interval and drain time control knobs are in the “RESET” and “CLOSED” positions. Carefully slide out the battery box "Reset" "Closed" and install two new 1.5-volt AAA batteries. 2h - Test the unit by turning the drain time knob to the “OPEN” position. You should hear the sound of the motor within 5 seconds. Turn the drain time knob back to the “CLOSED” position ready for setting. NOTE: If you do not hear the sound of the motor, check that the batteries are installed correctly.
2i - Ensure that the reset interval and drain time knobs are in the “RESET” and “CLOSED” positions. NOTE: The first time you program the Electronic Release Valve it will not begin to operate until after a time delay equal to the setting of the reset interval knob you select. The Electronic Release Valve starts to keep time when you set it. It is important that you set the timer at the hour you want it to operate.
POLLUTION FACTORS The following factors can be used as a guide to determining the volume of water to be diverted. POLLUTION FACTOR FOR THE ROOF MINIMAL POLLUTION SUBSTANTIAL POLLUTION DIVERT 0.5L PER M 2 (0.0125 GALLONS PER FT 2) DIVERT 2L PER M 2 (O.05 GALLONS PER FT 2) Open field, no trees, no bird droppings, clean environment Leaves and debris, bird droppings, various animal matter, e.g. dead insects, skinks, etc. The above quantum are the results of preliminary testing.
REFERENCE CHART 1 In-feed from the roof 8 Ball seat 2 To the tank 9 Electronic Release Valve 3 Diverter Chamber 10 Pipe/Wall Brackets 4 Sealing Ball 11 End Coupling 5 Catch All Tee 12 Transparent, Rapid Release Exit Funnel 6 Chamber Inlet 7 Chamber Outlet 13 25mm x 20mm reducing adaptor rainharvesting.
Product Specifications First Flush w/ Catch-All Tee and Electronic Valve C F A D A B E B Dimensions & Pipe Fittings COUNTRY CODE A B C D E F Australia WDDP20 100 F 100 F 283 230 304 140 EU WDDP620 100 F / 105 F / 110 F 100F / 105 F / 110 F 283 230 304 140 South Africa WDDP320 80 F 110 F 287 230 304 140 New Zealand WDDP220 80 F 110 F 287 230 304 140 USA WDDP120 4" SCH40 F / SDR35 F 4" SCH40 F / SDR35 F 11.1" 9.1" 12" 5.
Maintenance IIt’s important to ensure that your first flush diverter outlet remains clear of any debris. If your outlet becomes blocked, the chamber will not empty and the first flush of water will not be diverted when it rains. To ensure the flow of water out through your diverter’s outlet, periodically check the transparent, rapid release exit funnel for any build-up of matter (Remove primary filter and clean if required). Periodically check that the Electronic Release valve batteries have charge.
For more information or to find out how we can help, just give us a call on +61 7 3248 9600 Or visit our website at rainharvesting.