Specifications

14 WS-PRO LT weather station
N
N

FIGURE13WindDirectionAlignment
5. FirmlytightentheUBoltnuts
6. Confirmtheweatherstationislevelbyviewingthebull’slevelontopoftheweatherstation
(seeFigure
14).Minoradjustmentscanbemadebyplacingshimsbetweentheweatherstation
baseandthetopofthepole.
Bull’slevel
FIGURE14Bull'sLevelontopoftheweatherstation
7. Connectthepowersourcethatwillrechargetheinternalsealedrechargeablebattery.For
SolarPoweredweatherstationsfollowinstructionsbelow.
8. Removetheredcapfromthesolarradiationsensor(Figure15).
FIGURE15Solar
Radiation
Sensor
9. Properlygroundtheweatherstationbyconnectinga#10gaugeorlargerwiretotheearth
groundluglocatedonthebaseoftheweatherstation.ReferAppendixA
forgrounding
recommendations.
10. Refertosection2.5CommunicationWiringfordirectconnectweatherstations.