Specifications

Field Control Systems
23www.rainbird.com
ADVANCED CONTROL TECHNOLOGIES
IC System™
SPECIFICATIONS
System Capacity*: 750 ICMs per Output Wire Path,
1500 ICMs per Output Driver Board, 3000 ICMs
per IC Interface (ICI), up to 36,000 ICMs with Cirrus
* Specific System Capacity is dependent on the Central
Control System
ICI Electrical Input: 100 VAC Nominal 91-110 VAC @
60 HZ +/- 2 HZ,115 VAC Nominal 98-132 VAC,
220-240 VAC Nominal 208-255 VAC
Electrical Output: 28.5 VAC, 1.25 AMP Per Wire Path
Active Stations: No electrical limit only limited
by hydraulics of pipe network and size of
pump station
ICM Current Requirements: Varies based on wire
path length Nominal Current Draw is 0.33 mA
on 5000 feet (1500 meters) of wire
Grounding Requirements: ICSD to be grounded at
less than 50 ohms every 500 feet (150 meters) or
15 ICMs whichever is less. The central control is to
be grounded with less than 10 ohms of resistance
Compliance: CE, FCC, UL
Environment:
Working Range: 32° F to 122° F (0° C to 50° C)
Storage Temperature: -40° F to 150° F
(-40° C to 65° C)
Operating and Storage Humidity: 100%
Dimensions:
ICM: 2.23" x 1.70" (57 mm x 43 mm)
ICSD: 2.00" x 1.41" (51 mm x 43 mm)
Compatibility: Rain Bird 700/751 Series Rotors,
Rain Bird EAGLE™ 700 and 900 Series Rotors**
and Rain Bird PES-B, PEB, PGA, EFB, and BPE
Electric Valves with ICM Adapter
** Note EAGLE Rotors sold before 6/2009 will have a random
orientation of the ICM relative to the Selector Housing
Maximum Wire Paths: Two (2) Outputs per IC
Driver Board and Up to four (4) total per ICI
and Multiple Branches Per Wire Path
STATUS: OK!
VOLTAGE: GOOD!
RUN TIME: 12 MIN
INTELLIGENCE BUILT INTO EVERY ICM
Built-in Surge Protection
Computerized Field Control
Fast Communication
On-board Intelligence