Full Product Manual

Table Of Contents
Calculate System Run Time Page 47
TABLE 6-3: MAXIMUM SYSTEM RUN TIME FOR MEDIUM SOIL
Watering Depth Emitter
Spacing
Emitter Flow
(GPH)
Maximum Run
Time
3 inches Use Xeri-Sprays or Xeri-Pops
6 inches 12 inches 0.5
1.0
2.0
26 minutes
13 minutes
7 minutes
9 inches 18 inches 0.5
1.0
2.0
89 minutes
45 minutes
22 minutes
12 inches 24 inches 0.5
1.0
2.0
211 minutes
106 minutes
53 minutes
18 inches 36 inches 0.5
1.0
2.0
713 minutes
357 minutes
178 minutes
24 inches 48 inches Use individual emitters based on
plant needs.
Available Water = 2.0"/ft.; Application Efficiency = 85%;
Allowable Depletion = 30%
TABLE 6-4: MAXIMUM SYSTEM RUN TIME FOR FINE SOIL
Watering Depth Emitter
Spacing
Emitter Flow
(GPH)
Maximum Run
Time
3 inches 12 inches 0.5
1.0
2.0
16 minutes
8 minutes
4 minutes
6 inches 24 inches 0.5
1.0
2.0
132 minutes
66 minutes
33 minutes
9 inches 36 inches 0.5
1.0
2.0
446 minutes
223 minutes
111 minutes
12 inches 48 inches Use individual emitters based on
plant needs.
Available Water = 2.5"/ft.; Application Efficiency = 85%;