Follow this procedure to charge the ToxiRAE Pro PID (the procedure is applicable to the
instrument with or without the rubber boot installed):
1. Plug the AC/DC adapter into the ToxiRAE Pro PID’s cradle.
2. Plug the AC/DC adapter into the wall outlet.
3. Place the ToxiRAE Pro PID into the cradle and press down until it is locked in
place.
The ToxiRAE Pro PID begins charging automatically. The LED in the cradle should
glow red to indicate charging. When charging is complete, the LED in the cradle glows
green.
WARNING!
To reduce the risk of ignition of hazardous atmospheres, recharge the instrument
only in areas known to be non-hazardous. Remove and replace batteries only in
areas known to be non-hazardous.
5.1. Removing The ToxiRAE Pro PID From The Charging
Cradle
To remove the ToxiRAE Pro PID from its charging cradle, press down on the latch
release on the back of the charging cradle while slightly tilting the ToxiRAE Pro PID
toward the front of the cradle, and lift it out.
5.2. Low Voltage Shutoff
When the battery’s charge falls below the shutoff voltage, the ToxiRAE Pro PID then
turns itself off. Recharge the battery by placing the ToxiRAE Pro PID in its cradle (the
cradle should be connected to the AC adapter).