B. Firmware Program. Software ZigBit Firmware Programmer V1.32
1. Select firmware file, *.srec
2. Select correct com port
3. Click “Program”, then Reset RAEMesh2 module in 30 seconds
4. Waiting for program successful.
C. Configure RAEMesh2 Application. Software SSCOM32.exe, RMCI.
1. Set UID/MAC address
5B 2C 4E xx xx xx xx xx xx xx xx 5D
The last two bytes must not set to 0x0000 ~ 0x0010, 0xFFF0-0xFFFF
2. Set PANID
5B 26 44 xx xx 5D = Set PanId, xxxx(0x0000-0x03E7)
3. Set Channel
5B 25 34 xx 5D = Set channel number
4. Set Tx Power
5B 25 3C xx 5D = Set Tx power
5. Set Application Type
5B 24 30 5D = Enable GTW function
5B 24 32 5D = Enable RTR function
5B 24 46 5D = Enable STD function
6. Set Debug Off
5B 25 FE 00 5D
Note:
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.