User Manual

8
Product Marking
The MicroRAE (PGM-2600) is certified according to the IECEx scheme, ATEX and CSA for US
and Canada under the intrinsic safety method of protection.
The PGM-2600 is marked with the following information:
RAE SYSTEMS
3775 N. 1
st
. St., San Jose
CA 95134, USA
Type PGM-2600.
Serial No/barcode: XXXX-XXXX-XX
IECEx SIR
15.0039X
Ex ia d IIC T4 Gb
Ex ia I Ma
0575
SIRA 15 ATEX 2080X
II 2G Ex ia d IIC T4
Gb
I M1 EX ia I Ma
-20º C < Tamb < +60º C
Um: 6V
Battery pack: M03-3004-000
Warning: Substitution of components may impact intrinsic safety
Avertissement: La substitution de composants peut compromettre la securité intrinsèque
WARNING: Read and understand instruction manual before operation or servicing.
AVERTISSEMENT: Lisez et comprenez le manual d’instructions avant d’utiliser ou
service.
WARNING: Substitution of components may impact intrinsic safety.
AVERTISSEMENT: La substitution de composants peut compromettre la sécurité
intrinsèque
WARNING: To prevent ignition of a hazardous atmosphere, batteries must only be
charged in an area known to be non-hazardous. Um = 6.0V. Use only approved charger/
AVERTISSEMENT: Afin de prevenir l’inflammation d’atmosphères dangereuse, ne
charger le jeu de batteries que dans des emplacement designés non dangereux. Um = 6V
Utilisez uniquement un chargeur approuvé.
Only use approved battery pack: M03-3004-000
Only charge the battery in safe area in the ambient temperature range 0°C ≤ T
amb
≤ 40°C