User Manual
52
14.2. Alarm Signal Summary
Alarm Summary
Alarm Type
Buzzer & LED
Display
Vibration
Reading
Backlight
Priority
Super Alarm
4 beeps/sec
“Mandown Alarm” screen
400ms
-
On
Highest
Man Down Alarm
3 beeps/sec
“Mandown Alarm” screen
400ms
-
On
Man Down
Warning
2 beeps/sec
“OK” screen
400ms
-
On
Max
3 beeps/sec
“MAX” at sensor location,
ALARM icon on
400ms
Blinking
reading
On
Over Range
3 beeps/sec
“Over” at sensor location,
ALARM icon on
400ms
Blinking
maximum
reading
On
High
3 beeps/sec
“HIGH” at sensor location,
ALARM icon on
400ms
Blinking
reading
On
Low
3 beeps/sec
“LOW” at sensor location,
ALARM icon on
400ms
Blinking
reading
On
Negative
1 beep/sec
“NEG” at sensor location,
ALARM icon on
400ms
Blinking
“0”
On
STEL
1 beep/sec
“STEL” at sensor location,
ALARM icon on
400ms
Blinking
reading
On
TWA
1 beep/sec
“TWA” at sensor location,
ALARM icon on
400ms
Blinking
reading
On
Calibration
Failure
1 beep/sec
“CAL” at sensor location,
ALARM icon on
400ms
Blinking
reading
On
Bump Failure
1 beep/sec
“Bump” at sensor location,
ALARM icon on
400ms
Blinking
Reading
On
Datalog Full
1 beep/sec
Blinking datalog symbol
400ms
Reading
On
Calibration Due
-
“CAL” at sensor location
-
Blinking
Reading
-
Bump Test Due
-
“Bump” at sensor location
-
Blinking
Reading
-
Battery
1 beep/min
Blinking battery icon
400ms
Reading
Stays as is
Network Lost
1 beep/sec
Blinking radio icon
400ms
Reading
On
Network Joined
1 beep
Radio icon
400ms
Reading
-
Comfort Beep
1 beep/min
No LED flash
-
-
Reading
-
Lowest
Notes
“Negative” means that the reading is below zero.
“Network Lost” means that the MicroRAE has lost wireless connectivity with its network.
“Network Joined” means that the MicroRAE has joined a wireless network.
“CAL” includes Span calibration failure, Zero/fresh air calibration failure.
Zero/fresh air failure is only supported by LEL and oxygen sensors.