Product specifications

DMD1050 Satellite Modem Board Web Browser
Rx Buffer Level (Fill %): {0 – 100%}
Displays the status of the Doppler Buffer. This window is above
the Gel Tab area.
RX Buffer Reset (ENTER) Allows the user to re-center the Doppler Buffer when <ENTER>
is pressed on the web browser screen.
Rx Bit Errors: Displays the current error count from the Viterbi Decoder.
+1.5V TX Supply Displays the measured voltage of the 1.5 Volt Tx power bus
located inside the modem.
+1.5V RX Supply Displays the measured voltage of the 1.5 Volt Rx power bus
located inside the modem.
+3.3V Supply Displays the measured voltage of the +3.3 Volt power bus
located inside the modem.
+5V Supply Displays the measured voltage of the +5 Volt power bus located
inside the modem.
+12V Supply Displays the measured voltage of the +12 Volt power bus located
inside the modem.
+20V Supply Displays the measured voltage of the +20 Volt power bus located
inside the modem.
MN-DMD1050 7–34
Revision 9