Specifications
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations
MN-DMDREMOTEOP Revision 9 1–83
Opcode: <2500h> Command Up Converter Configuration
Command Data (15 Bytes)
<8> LO Frequency Hz
<1> Mix Select 0 = High side, 1 = Low side
<1> Reference Enable 0 = Disabled, 1 = Enabled
<1> Supply Voltage
Enable
0 = Disabled, 1 = Enabled
<1> FSK Communications
Select
0 = None, 1 = Codan, 2 = TerraSat, 3 = Amplus
<2> BUC Address
<1> BUC Output Enable 0 = Disabled, 1 = Enabled
Opcode: <2501h> Command Uplink RF
Command Data (8 Bytes)
<8> RF Hz
Opcode: <2502h> Command Down Converter Configuration
Command Data (12 Bytes)
<8> LO Frequency Hz
<1> Mix Select 0 = High side, 1 = Low side
<1> Reference Enable 0 = Disabled, 1 = Enabled
<1> Supply Voltage
Enable
0 = Disabled, 1 = Enabled
<1> Supply Voltage
Select
13, 16, 18, 24, 48
Opcode: <2503h> Command Downlink RF
Command Data (8 Bytes)
<8> RF Hz
Opcode: <2F61h> Command BUC FSK Pass Thru
Command Data (64 Bytes)
<64> BUC FSK Command
Data
Null Terminated ASCII string
Opcode: <2E06h> Query BUC FSK Pass thru Reply
Query Response (255 Bytes)
<255>
BUC FSK Reply Data Null Terminated ASCII string
The following opcode is for customer purchased and installed features only.
Opcode: <2450h> Query a Module's Installed Features (Customer Purchased)