Specifications

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations
MN-DMDREMOTEOP Revision 9 1–82
Opcode: <2C09h> Clear Modem Common Latched Alarm 2 (No Data)
Command Data (0 Bytes)
Opcode: <2C0Ah> Command Delete a Modem's Event Buffer
Command Data (1 Byte)
<1> Events to Delete 1 = delete one event (deletes first event in buffer) , 2 =
delete all events
Opcode: <2C0Bh> Command Soft Reset (No Data) (Stops petting the watch dog to restart the
processor)
Command Data (0 Bytes)
Opcode: <2490h> Query Up Converter Configuration
Query Response (22 Bytes)
<8> LO Frequency Hz
<1> Mix Select 0 = High side, 1 = Low side
<1> Reference Enable 0 = Disabled, 1 = Enabled
<1> Supply Voltage
Enable
0 = Disabled, 1 = Enabled
<1> FSK Communications
Select
0 = None, 1 = Codan, 2 = TerraSat, 3 = Amplus
<2> BUC Address
<1> BUC Output Enable 0 = Disabled, 1 = Enabled
<2> BUC Carrier Level Implied decimal point, dBm
<4> BUC Summary
Status
<1> BUC Temperature Degrees, C
Opcode: <2491h> Query Uplink RF
Query Response (8 Bytes)
<8> RF Hz
Opcode: <2492h> Query Down Converter Configuration
Query Response (12 Bytes)
<8> LO Frequency Hz
<1> Mix Select 0 = High side, 1 = Low side
<1> Reference Enable 0 = Disabled, 1 = Enabled
<1> Supply Voltage
Enable
0 = Disabled, 1 = Enabled
<1> Supply Voltage
Select
13, 16, 18, 24, 48
Opcode: <2493h> Query Downlink RF
Query Response (8 Bytes)
<8> RF Hz