Specifications

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations
MN-DMDREMOTEOP Revision 9 1–43
<2> AUPC Minimum
Power
For DMD20 Signed value 0 to –2500 with implied
decimal point; (0.00 to –25.00 dBm) (two’s compliment)
For OM20 Signed value -2000 to -4500 with implied
decimal point; (-20.00 to -45.00 dBm)
<2> AUPC Maximum
Power
For DMD20 Signed value 0 to –2500 with implied
decimal point; (0.00 to –25.00 dBm) (two’s compliment)
For OM20 Signed value -2000 to -4500 with implied
decimal point; (-20.00 to -45.00 dBm)
<2> AUPC Nominal
Power
For DMD20 Signed value 0 to –2500 with implied
decimal point; (0.00 to –25.00 dBm) (two’s compliment)
For OM20 Signed value -2000 to -4500 with implied
decimal point; (-20.00 to -45.00 dBm)
Opcode: <2635h> Command AUPC Remote Configuration
Command Data (3 Bytes)
<1> AUPC Remote
Enable
0 = Off, 1 = EF AUPC
<1> AUPC Remote BB
Loopback
0 = Disabled, 1 = Enabled
<1> AUPC Remote 2047 0 = Disabled, 1 = Enabled
Opcode: <2636h> Command Modulator Reed Solomon N & K Codes and Interleaver Depth
Command Data (3 Bytes)
<1> Tx RS N Code 2 – 255, Reed-Solomon code word length
<1> Tx RS K Code 1 – 254, Reed-Solomon message length
<1> Tx RS Depth 4, 8, or 12
Opcode: <2638h> Command Modulator TPC Interleaver
Command Data (1 Byte)
<1> TPC Interleaver 0 = Disabled, 1 = Enabled
Opcode: <2640h> Command Modulator Async Configuration
Command Data (4 Bytes)
<1> ES Mode 0 = Normal, 1 = Enhanced
<1> ES Type 0 = RS232, 1 = RS485
<1> ES Baud Rate 0 =150, 1 = 300, 2 = 600, 3 = 1200, 4 = 2400, 5= 4800,
6 = 9600, 7 = 19200, 8 = 38400, 9 = 57600, 10 =
115200
<1> ES Data Bits 0 = 7 bits, 1 = 8 bits
Opcode: <2641h> Command Minor Alarm Relay Usage
Command Data (1 Byte)
<1> Minor Alarm Relay
Usage
0 = undefined, 1= IBS Usage, 2 = IBS & Minor Alarms,
3 = IBS, Minor Alarms and Major Alarms
Opcode: <2642h> Command Modulator Ethernet Terrestrial Interface Configuration
Command Data (4 Bytes)