Specifications
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations
MN-DMDREMOTEOP Revision 9 1–41
<11> Tx Circuit ID 11 ASCII characters, null terminated
Opcode: <2622h> Command Force Modulator Alarm Test
Command Data (1 Byte)
<1> Forced Alarm Test Bit 0 = Tx Major Alarm
Bits 1 – 7 = Spares
0 = Not Forced, 1 = Forced
Opcode: <2623h> Command Modulator Data Invert
Command Data (1 Byte)
<1> Data Invert 0 = None, 1 = Terrestrial, 2 = Baseband, 3 = Terrestrial
and Baseband
Opcode: <2625h> Clear a Modulator’s Latched Alarm 1 (No Data)
Command Data (0 Bytes)
Opcode: <2629h> Command AUPC Local Enable
Command Data (1 Byte)
<1> AUPC Local Enable 0 = Off, 1 = EF AUPC, 2 = Radyne AUPC
Opcode: <262Ah> Command AUPC Remote Enable
Command Data (1 Byte)
<1> AUPC Remote
Enable
0 = Off, 1 = EF AUPC
Opcode: <262Bh> Command AUPC Local CL Action
Command Data (1 Byte)
<1> AUPC Local CL
Action
0 = Hold, 1 = Nominal, 2 = Maximum
Opcode: <262Ch> Command AUPC Remote CL Action
Command Data (1 Byte)
<1> AUPC Remote CL
Action
0 = Hold, 1 = Nominal, 2 = Maximum
Opcode: <262Dh> Command AUPC Tracking Rate
Command Data (1 Byte)
<1> AUPC Tracking Rate 0 = 0.5 dB/Min, 1 = 1.0 dB/Min, 2 = 1.5 dB/Min, 3 = 2.0
dB/Min, 4 = 2.5 dB/Min, 5 = 3.0 dB/Min, 6 = 3.5 dB/Min,
7 = 4.0 dB/Min, 8 = 4.5 dB/Min, 9 = 5.0 dB/Min, 10 =
5.5 dB/Min, 11 = 6.0 dB/min
Opcode: <262Eh> Command AUPC Remote Baseband Loopback