Specifications

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations
MN-DMDREMOTEOP Revision 9 1–35
<2> AUPC Minimum
Power
For DMD20 Signed value 0 to –2500 with implied
decimal point; (0.00 to –25.00 dBm) (two’s compliment)
For OM20 Signed value -2000 to -4500 with implied
decimal point; (-20.00 to -45.00 dBm)
<2> AUPC Maximum
Power
For DMD20 Signed value 0 to –2500 with implied
decimal point; (0.00 to –25.00 dBm) (two’s compliment)
For OM20 Signed value -2000 to -4500 with implied
decimal point; (-20.00 to -45.00 dBm)
<2> AUPC Nominal
Power
For DMD20 Signed value 0 to –2500 with implied
decimal point; (0.00 to –25.00 dBm) (two’s compliment)
For OM20 Signed value -2000 to -4500 with implied
decimal point; (-20.00 to -45.00 dBm)
<1> TMT Pattern Enable Reserved
<1> TMT Pattern Length Reserved
<1> Terrestrial Framing 0 = DVB 188, 1 = DVB 204, 2 = NONE
<1> Alarm 4 Mask Bit 0 = LBST BUC DC Current Alarm
Bit 1 = LBST BUC DC Voltage Alarm
Bit 2 = Ethernet WAN Alarm
Bit 3 = LBST BUC PLL Alarm
Bit 4 = LBST BUC Over Temperature Alarm
Bit 5 = LBST BUC Summary Alarm
Bit 6 = LBST BUC Output Enable Alarm
Bit 7 = LBST BUC Communications Alarm
0 = Mask, 1 = Allow
<1> TPC Interleaver 0 = Disabled, 1 = Enabled
<1> Ethernet Flow Control 0 = Disabled, 1 = Enabled
<1> Ethernet Daisy Chain 0 = Disabled, 1 = Enabled (Port 4)
<1> ES Mode 0 = Normal, 1 = Enhanced
<1> ES Type 0 = RS232, 1 = RS485
<1> ES Baud Rate 0 =150, 1 = 300, 2 = 600, 3 = 1200, 4 = 2400, 5= 4800,
6 = 9600, 7 = 19200, 8 = 38400, 9 = 57600, 10 =
115200
<1> ES Data Bits 0 = 7 bits, 1 = 8 bits
<1> Carrier Enable Delay 0 – 255 in seconds
<1> SCC Control Ratio 1 = 1/1, 2 = 1/2, 3 = 1/3, 4 = 1/4, 5 = 1/5, 6 = 1/6, 7 =
1/7
<4> SCC In band Rate 300 to 200000 bps
<2> LBST BUC DC
Voltage Alarm Lower
Threshold
Volts, Implied decimal point, 10 = 1.0V (00.0 V to 55.0
V)
<2> LBST BUC DC
Voltage Alarm Upper
Threshold
Volts, Implied decimal point, 10 = 1.0V (00.0 V to 55.0
V)
<2> LBST BUC DC
Current Alarm Lower
Threshold
Amps, Implied decimal point, 1000 = 1.000A (0.000 A
to 8.000 A)
<2> LBST BUC DC
Current Alarm Upper
Threshold
Amps, Implied decimal point, 1000 = 1.000A (0.000 A
to 8.000 A)
<2> Compensation TX Power Level offset from 0 to 10 (0.0 dBm to 1.0
dBm), Implied decimal point
<1> Forced Alarm Test Bit 0 = Tx Major Alarm
Bits 1 – 7 = Spares
0 = Not Forced, 1 = Forced