Remote Operations For the DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Manuals IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. This manual is subject to change without prior notice.
Remote Operations For the DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Manuals Part Number MN-DMDREMOTEOP Revision 9 Copyright © 2013 Comtech EF Data. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.
This page is intentionally blank.
Table of Contents PREFACE .................................................................................................................................... V About this Manual ...................................................................................................................................... v Patents and Trademarks ............................................................................................................................ v Product Support ..............................
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol CHAPTER 3. 3.1 Table of Contents WEB BROWSER ............................................................................................. 3–1 Web Browser User Interfaces .................................................................................................... 3–1 3.2 Configuring Your PC ................................................................................................................. 3–2 3.2.1 LED Indicators ..........
Preface About this Manual This manual describes the installation and operation for the Radyne DMD Remote Operations. This is a technical document intended for earth station engineers, technicians, and operators responsible for the operation and maintenance of the Radyne DMD Remote Operations. Patents and Trademarks See all of Comtech EF Data’s Patents and Patents Pending at http://patents.comtechefdata.com. Comtech EF Data acknowledges that all trademarks are the property of the trademark owners.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Preface Safety Compliance Examples of Multi-Hazard Formats EN 60950 Applicable testing is routinely performed as a condition of manufacturing on all units to ensure compliance with the requirements of the EN 60950 Safety of Information Technology Equipment (Including Electrical Business Machines) safety standard. This equipment meets the Safety of Information Technology Equipment specification as defined in EN60950.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Preface Warranty Policy Comtech EF Data products are warranted against defects in material and workmanship for a specific period from the date of shipment, and this period varies by product. In most cases, the warranty period is two years. During the warranty period, Comtech EF Data will, at its option, repair or replace products that prove to be defective.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Preface Comtech EF Data Headquarters http://www.comtechefdata.com Comtech EF Data Corp. 2114 West 7th Street Tempe, Arizona USA 85281 +1.480.333.
Chapter 1. Remote Operations 1.1 Introduction The Remote Protocols for the DMD20, DMD20LBST, DMD50, DMD2050, DMD2050E, DMD1050 and OM20 are similar in design and utilize the same protocol platforms. This document should be used as the primary source for identifying the various protocol structures and control menus for products listed below. The most current Remote Protocols manual can be accessed from the Radyne web site at http://www.comtechefdata.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations This specification is applicable to the DMD20/20LBST, DMD50, DMD2050, DMD2050E, DMD1050 and OM20 Modems. Any reference to the DMD20 in this document can be applicable to any one of these three modems. For configuration setup, refer to the product manuals. 1.2.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations All nodes on a given control bus have a unique address that must be defined. : The Destination Identifier serves as a pointer to the multi-drop destination device that indicates where the message is to be sent. : The Frame Sequence Number (FSN) is a tag with a value from 0 through 255 that is sent with each message.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations This remainder is the checksum for the frame. 242 (decimal) = F2h = 11110010b = 1.2.3 Frame Description and Bus Handshaking: In a Monitor and Control environment, every message frame on a control bus port executes as a packet in a loop beginning with a wait-for-SYNC-character mode.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol 1.2.4 Remote Operations Global Response Operational Codes: In acknowledgment (response) packets, the operational code field of the message packet is set to 0 by the receiving devices when the message intended for the device is evaluated as valid.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol MPARM_INTERFACECOMMUNICATION_ERROR MPARM_SYMBOLRATE_ERROR MPARM_NOTIMPLEMENTED_ERROR MPARM_SUMMARYFAULT_ERROR MPARM_DATAINVERT_ERROR MPARM_ESCSOURCE_ERROR MPARM_AUPCLOCALENABLE_ERROR MPARM_AUPCREMOTEENABL_ERROR MPARM_AUPCLOCALCLACTION_ERROR MPARM_AUPCREMOTECLACTION_ERROR MPARM_AUPCTRACKINGRATE_ERROR MPARM_AUPCREMOTEBBLOOPACK_ERROR MPARM_AUPCREMOTE2047_ERROR MPARM_AUPCEBNO_ERROR MPARM_AUPCMINPOWER_ERROR MPARM_AUPCMAXPOWER_ERROR MPARM_AUPCNOMINAPOWER_
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations DPARM_NOTIMPLEMENTED_ERROR DPARM_DATAINVERT_ERROR DPARM_SUMMARYFAULT_ERROR DPARM_EXTERNALEXCSOURCE_ERROR DPARM_ASYNCMODE_ERROR DPARM_ASYNCBAUDRATE_ERROR DPARM_ASYNCTYPE_ERROR DPARM_ASYNCDATABITS_ERROR DPARM_REACQ_SWEEP_ERROR DPARM_ESCCHANNEL1VOLUME_ERROR DPARM_ESCCHANNEL2VOLUME_ERROR DPARM_ESCOVERHEADTYPE_ERROR DPARM_TPCINTERLEAVER_ERROR DPARM_FASTACQENABLE_ERROR DPARM_RFMTIMECONSTANT_ERROR MDPARM_MAPNUMBER_ERROR MDPARM_TIME_ERROR
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol RCU-340 1:1 Switch RCS-780 1:N Switch RMUX-340 Cross-Connect Multiplexer CDS-780 Clock Distribution System SOM-340 Second Order Multiplexer DMD-4500/5000 Modulator Section DMD-4500/5000 Demodulator Section RCU-5000 M:N Switch DMD20 Modulator DMD20 Demodulator DMD20 Modem DVB3030 Video Modulator, DM240 RCS20 M:N Switch RCS10 M:N Switch RCS11 1:1 Switch Reserved for future equipment types Remote Operations 03 04 05 06 07 08 09 10 20 21 22 23 24 25 2
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations Volatile Section. If a remote M&C queries two pieces of Radyne equipment with different revision software, they may respond with two different sized packets. The remote M&C MUST make use of the non-volatile count value to index to the start of the Volatile Section.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations To maintain frame synchronization, the IOPT keeps track of error-laden packets and packets intended for other equipment for the duration of each received packet. Once the packet is complete, the IOPT invokes an I/O wait state and searches for the next character. 1.2.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations : Frame sequence number ensures correct packet acknowledgment and data transfers (1 byte). : This byte identifies the message type associated with the information data. The equipment processes the data according to the value in this field. Return error codes and acknowledgment are also included in this field (2 bytes). <...DATA...>: Information data.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations When new features are added to Radyne equipment, the control parameters are appended to the end of the Non-Volatile Section of the Remote Communications Specification, and status of the features, if any, are added at the end of the Volatile Section. If a remote M & C queries two pieces of Radyne equipment with different revision software, they could respond with two different sized packets.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Query CNC Status Query BUC FSK Pass Thru Reply Command Command Up converter Configuration Command Uplink RF Command Down converter Configuration Command Downlink RF Command Modem Control Mode Command Modulator Configuration Command Modulator Frequency Command Modulator Strap Code Command Modulator Data Rate Command Modulator Filter Mask Command Modulator Modulation Type Command Modulator Convolutional Encoder Command Modulator Differential Encoder C
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Command AUPC Local Configuration Command AUPC Remote Configuration Command Modulator Reed Solomon N & K Codes and Interleaver Depth Command Modulator TPC Interleaver Command Modulator Async Configuration Command Minor Alarm Relay Usage Command Modulator Ethernet Terrestrial Interface Configuration Command Demodulator Configuration Command Demodulator Frequency Command Demodulator Data Rate Command Demodulator Strap Code Command Demodulator Sweep Bou
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Command Clear Latched Alarms Command Set Time Command Set Date Command Set Time and Date Clear Modem Common Latched Alarm 1 Clear Modem Common Latched Alarm 2 Command Delete Modem Event Buffer Command Soft Reset Command BUC FSK Pass Thru 1.5 Detailed Command Descriptions: 1.5.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Convolutional Encoder <1> <1> <1> Reed Solomon Scrambler Control Scrambler Type <2> Transmit Power Level <1> <1> Differential Encoder Carrier Control <1> Carrier Selection <1> <1> <1> <1> <1> <1> Spectrum TX Test Pattern Clock Control Clock Polarity SCT Source Satellite Framing <1> Drop Mode <30> Drop Map <1> T1D4 Yellow Alarm Select MN-DMDREMOTEOP Revision 9 Remote Operations 0 = None, 1 = Viterbi ½, 2 = Viterbi 2/3 (DVB Onl
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> Forced Backward Alarms Alarm 1 Mask <1> Alarm 2 Mask <1> Common Alarm 1 Mask <1> Common Alarm 2 Mask <11> <1> <1> <1> Tx Circuit ID Tx ESC Ch 1 Volume Tx ESC Ch 2 Volume Tx Interface Type MN-DMDREMOTEOP Revision 9 Remote Operations Bit 0 = Backward Alarm 1 IDR and IBS Bit 1 = Backward Alarm 2 IDR Bit 2 = Backward Alarm 3 IDR Bit 3 = Backward Alarm 4 IDR Bits 4 & 5 = Reserved Bit 6 = IBS Prompt Bit 7 = IBS Service 0 = None, 1 =
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> Tx Terrestrial Loopback Tx Baseband Loopback Drop Status Mask <1> <1> <1> <1> Tx RS N Code Tx RS K Code Tx RS Depth Data Invert <1> <1> <1> <1> BPSK Symbol Pairing IDR Overhead Type Terminal Emulation Terminal Baud Rate <1> <1> FM Orderwire Mode FM Orderwire Test Tone AUPC Local Enable AUPC Remote Enable AUPC Local CL Action AUPC Remote CL Action AUPC Tracking Rate <1> <1> <1> <1> <1> <1> <1> <1> <2> AUPC Remote BB Loopback AUPC
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> Terrestrial Framing Alarm 4 Mask <1> <1> <1> <1> <1> <1> TPC Interleaver Ethernet Flow Control Ethernet Daisy Chain ES Mode ES Type ES Baud Rate <1> <1> <1> ES Data Bits Carrier Enable Delay SCC Control Ratio <4> <2> <2> SCC In band Rate LBST BUC DC Voltage Alarm Lower Threshold LBST BUC DC Voltage Alarm Upper Threshold LBST BUC DC Current Alarm Lower Threshold LBST BUC DC Current Alarm Upper Threshold Compensation <1> Forced Alarm
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> <1> <4> <1> EBEM overhead channel rate EBEM embedded channel EBEM ITA EBEM encryption EBEM Ethernet rate Ethernet HDLC <1> Control Mode <1> <1> Revision Number Alarm 1 <1> Alarm 2 <1> Common Alarm 1 <1> Common Alarm 2 <1> Latched Alarm 1 <1> Latched Common Alarm 1 <1> MN-DMDREMOTEOP Revision 9 Remote Operations 0 = Off, 1 = 8K, 2 = 16K, 3 = 24K, 4 = 32K, 5 = 40K, 6 = 48K, 7 = 56K, 8 = 64K 0 = Off, 1 = On 0 = Disabled, 1 =
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Latched Common Alarm 2 <1> Drop Status <1> Online Flag <1> <1> <1> +5V Voltage +12V Voltage -12V Voltage <2> <1> <1> Reserved ESC Source Backward Alarms <2> <1> <4> <1> AUPC Remote Test 2047 Mantissa AUPC Remote Test 2047 BER Exponent Reserved Symbol Rate Latched Alarm 2 <1> Alarm 4 <1> MN-DMDREMOTEOP Revision 9 Remote Operations Bit 0 = TERR FPGA Config Bit 1 = CODEC FPGA Config Bit 2 = CODEC Device Config Bit 3 = TRANSEC Powe
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Latched Alarm 4 <1> <2> Reserved LBST BUC DC Current LBST BUC DC Voltage FSK Test Result BUC Carrier Level BUC Summary Status BUC Temperature <2> <1> <2> <4> <1> Opcode: <2448h> <1> <4> <2> <1> <4> <4> <4> <1> <1> Remote Operations Bit 0 = LBST BUC DC Current Alarm Bit 1 = LBST BUC DC Voltage Alarm Bit 2 = Ethernet WAN Alarm Bit 3 = LBST BUC PLL Alarm Bit 4 = LBST BUC Over Temperature Alarm Bit 5 = LBST BUC Summary Alarm Bit 6 = LBST B
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Convolutional Encoder <1> <1> <1> Reed Solomon Scrambler Control Scrambler Type <2> Transmit Power Level <1> <1> Differential Encoder Carrier Control <1> Carrier Selection <1> <1> <1> <1> <1> <1> Spectrum TX Test Pattern Clock Control Clock Polarity SCT Source Satellite Framing <1> Drop Mode <30> Drop Map <1> T1D4 Yellow Alarm Select MN-DMDREMOTEOP Revision 9 Remote Operations 0 = None, 1 = Viterbi ½, 2 = Viterbi 2/3 (DVB Onl
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> Forced Backward Alarms Alarm 1 Mask <1> Alarm 2 Mask <1> Common Alarm 1 Mask <1> Common Alarm 2 Mask <11> <1> <1> <1> Tx Circuit ID Tx ESC Ch 1 Volume Tx ESC Ch 2 Volume Tx Interface Type MN-DMDREMOTEOP Revision 9 Remote Operations Bit 0 = Backward Alarm 1 IDR and IBS Bit 1 = Backward Alarm 2 IDR Bit 2 = Backward Alarm 3 IDR Bit 3 = Backward Alarm 4 IDR Bits 4 & 5 = Reserved Bit 6 = IBS Prompt Bit 7 = IBS Service 0 = None, 1 =
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> Tx Terrestrial Loopback Tx Baseband Loopback Drop Status Mask <1> <1> <1> <1> Tx RS N Code Tx RS K Code Tx RS Depth Data Invert <1> <1> <1> <1> BPSK Symbol Pairing IDR Overhead Type Terminal Emulation Terminal Baud Rate <1> <1> FM Orderwire Mode FM Orderwire Test Tone AUPC Local Enable AUPC Remote Enable AUPC Local CL Action AUPC Remote CL Action AUPC Tracking Rate <1> <1> <1> <1> <1> <1> <1> <1> <2> AUPC Remote BB Loopback AUPC
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> Terrestrial Framing Alarm 4 Mask <1> <1> <1> <1> <1> <1> TPC Interleaver Ethernet Flow Control Ethernet Daisy Chain ES Mode ES Type ES Baud Rate <1> <1> <1> ES Data Bits Carrier Enable Delay SCC Control Ratio <4> <2> <2> SCC In band Rate LBST BUC DC Voltage Alarm Lower Threshold LBST BUC DC Voltage Alarm Upper Threshold LBST BUC DC Current Alarm Lower Threshold LBST BUC DC Current Alarm Upper Threshold Compensation <1> Forced Alarm
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> <1> <1> <4> <1> EBEM overhead channel rate EBEM embedded channel EBEM ITA EBEM encryption EBEM Ethernet rate Ethernet HDLC Opcode: <240Bh> Remote Operations 0 = Off, 1 = 8K, 2 = 16K, 3 = 24K, 4 = 32K, 5 = 40K, 6 = 48K, 7 = 56K, 8 = 64K 0 = Off, 1 = On 0 = Disabled, 1 = Enabled 0 = Disabled, 1 = Enabled 4800 to 52000000 0= Radyne, 1 = Comtech, 2 = Managed 570 Query a Modulator's Status <1> Control Mode <1> <1> Revision Number Alarm 1
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Latched Common Alarm 1 <1> Latched Common Alarm 2 <1> Drop Status <1> Online Flag <1> <1> <1> +5V Voltage +12V Voltage -12V Voltage <2> <1> <1> Reserved ESC Source Backward Alarms <2> AUPC Remote Test 2047 Mantissa AUPC Remote Test 2047 BER Exponent Reserved Symbol Rate Latched Alarm 2 <1> <1> <4> <1> MN-DMDREMOTEOP Revision 9 Remote Operations Bit 0 = -12V Alarm Bit 1 = +12V Alarm Bit 2 = +5V Alarm Bits 3 - 5 = Reserved Bit 6 =
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Alarm 4 <1> Latched Alarm 4 <1> <2> Reserved LBST BUC DC Current LBST BUC DC Voltage FSK Test Result BUC Carrier Level BUC Summary Status BUC Temperature <2> <1> <2> <4> <1> Opcode: <2405h> Remote Operations Bit 0 = LBST BUC DC Current Alarm, 1 = Fail Bit 1 = LBST BUC DC Voltage Alarm, 1 = Fail Bit 2 = Ethernet WAN Alarm, 1 = Fail Bit 3 = LBST BUC PLL Alarm, 1 = Fail Bit 4 = LBST BUC Over Temperature Alarm, 1 = Fail Bit 5 = LBST BUC Sum
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Latched Alarm 2 <1> Latched Alarm 4 Opcode: <2408h> Remote Operations Bit 0 = Terrestrial Clock Activity Detect Bit 1 = Internal Clock Activity Detect Bit 2 = Tx Sat Clock Activity Detect Bit 3 = Tx Data Activity Detect Bit 4 = Terrestrial AIS.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Common Alarm 2 <1> Backward Alarms <1> Alarm 4 Opcode: <2451h> Remote Operations Bit 0 = TERR FPGA Config, 1 = Fail Bit 1 = CODEC FPGA Config, 1 = Fail Bit 2 = CODEC Device Config, 1 = Fail Bit 3 = TRANSEC Power Test, 1 = Fail Bit 4 = +1.5 V Rx Alarm, 1 = Fail Bit 5 = +1.5 V TX Alarm, 1 = Fail Bit 6 = +3.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <4> Data Rate <4> External Clock Frequency <4> External Reference Frequency Frequency Reference Source Modulation Type <1> <1> <1> Convolutional Encoder <1> <1> <1> Reed Solomon Scrambler Control Scrambler Type <2> Transmit Power Level <1> <1> Differential Encoder Carrier Control <1> Carrier Selection <1> <1> <1> <1> <1> Spectrum TX Test Pattern Clock Control Clock Polarity SCT Source MN-DMDREMOTEOP Revision 9 Remote Operations B
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Satellite Framing <1> Drop Mode <30> Drop Map <1> T1D4 Yellow Alarm Select Forced Backward Alarms <1> <1> Alarm 1 Mask <1> Alarm 2 Mask <1> Common Alarm 1 Mask <1> Common Alarm 2 Mask <11> <1> <1> Tx Circuit ID Tx ESC Ch 1 Volume Tx ESC Ch 2 Volume MN-DMDREMOTEOP Revision 9 Remote Operations 0 = No Framing, 1 = 96K IDR, 2 = 1/15 IBS, 3 = EF AUPC 1/15, 4 = DVB, 5 = EDMAC, 6 = SCC, 7 = 96K, 8 = Efficient D&I, 9 = Ebem 0 = Disa
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Tx Interface Type <1> <1> Tx Terrestrial Loopback Tx Baseband Loopback Drop Status Mask <1> <1> <1> <1> Tx RS N Code Tx RS K Code Tx RS Depth Data Invert <1> <1> <1> <1> BPSK Symbol Pairing IDR Overhead Type Terminal Emulation Terminal Baud Rate <1> <1> FM Orderwire Mode FM Orderwire Test Tone AUPC Local Enable AUPC Remote Enable AUPC Local CL Action AUPC Remote CL Action AUPC Tracking Rate <1> <1> <1> <1> <1> <1> <1> <1> <2> AUPC
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <2> AUPC Minimum Power <2> AUPC Maximum Power <2> AUPC Nominal Power <1> <1> <1> <1> TMT Pattern Enable TMT Pattern Length Terrestrial Framing Alarm 4 Mask <1> <1> <1> <1> <1> <1> TPC Interleaver Ethernet Flow Control Ethernet Daisy Chain ES Mode ES Type ES Baud Rate <1> <1> <1> ES Data Bits Carrier Enable Delay SCC Control Ratio <4> <2> <2> SCC In band Rate LBST BUC DC Voltage Alarm Lower Threshold LBST BUC DC Voltage Alarm Upper Thre
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Asynchronous InBand Rate <1> FSK Communications Select FSK Test Type <1> <2> <1> <1> <1> <1> <1> <1> <1> <1> <4> <1> BUC Address BUC Output Enable Minor Alarm Relay Usage Ethernet QOS Type Ethernet QOS QUEUE EBEM overhead channel rate EBEM embedded channel EBEM ITA EBEM encryption EBEM Ethernet rate Ethernet HDLC Opcode: <2602h> <4> Remote Operations 0 =150, 1 = 300, 2 = 600, 3 = 1200, 4 = 2400, 5= 4800, 6 = 9600, 7 = 19200, 8 = 38400,
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <4> Data Rate Remote Operations Binary value, 1 bps steps 2.4 Kbps to 20 Mbps for DMD20, DMD20LBST and OM20 2.4 Kbps to 52 Mbps for DMD2050, DMD2050E and DMD50 This command also turns the carrier off to protect the satellite. Opcode: <2605h> <1> Spectral Mask Opcode: <2606h> <1> Command a Modulator’s Filter Mask Command Data (1 Byte) 0 = INTELSAT 0.35, 18 = MIL-188-165A, 20 = DVB 0.20, 25 = DVB 0.25, 35 = DVB 0.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Opcode: <2608h> <1> <1> <1> <1> <1> <1> <2> Command Data (1 Byte) 0 = Disabled, 1 = T1-D4, 2 = T1-ESF, 3 = PCM-30, 4 = PCM-30C, 5 = PCM-31, 6 = PCM-31C, 7 = SLC-96, 8 = T1 D4 S, 9 = T1 ESF S Command a Modulator’s Output Level Transmit Power Level Opcode: <2610h> Command Data (1 Byte) 0 = Internal, 1 = SCR Command a Modulator’s Drop Mode Drop Mode Opcode: <260Fh> Command Data (1 Byte) 0 = Normal, 1 = Inverted, 2 = Auto Command a Modu
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Reed Solomon Remote Operations 0 = Disabled, 1 = Enabled This command also turns the Carrier off.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Tx Terrestrial Loopback Opcode: <2618h> <1> <1> <4> <4> <1> <1> Command Data (1 Byte) Reserved Command a Modulator’s Interface Type Tx Interface Type Opcode: <261Fh> Command Data (4 Bytes) Binary value, 8 kHz steps, 256 kHz to 10 MHz Command a Modulator’s T1D4 Yellow Alarm Selection T1D4 Yellow Alarm Select Opcode: <261Eh> Command Data (4 Bytes) Binary value, 1 Hz steps 2.4 kHz to 20 MHz For DMD20 2.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <11> Tx Circuit ID Opcode: <2622h> <1> <1> Command Data (1 Byte) Bit 0 = Tx Major Alarm Bits 1 – 7 = Spares 0 = Not Forced, 1 = Forced Command Modulator Data Invert Data Invert Opcode: <2625h> 11 ASCII characters, null terminated Command Force Modulator Alarm Test Forced Alarm Test Opcode: <2623h> Remote Operations Command Data (1 Byte) 0 = None, 1 = Terrestrial, 2 = Baseband, 3 = Terrestrial and Baseband Clear a Modulator’s Latched A
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> AUPC Remote BB Loopback Opcode: <262Fh> <1> <2> <2> <2> <2> <1> <1> <1> <1> <2> Command Data (2 Bytes) For DMD20 Signed value 0 to –2500 with implied decimal point; (0.00 to –25.00 dBm) (two’s compliment) For OM20 Signed value -2000 to -4500 with implied decimal point; (-20.00 to -45.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <2> AUPC Minimum Power <2> AUPC Maximum Power <2> AUPC Nominal Power Opcode: <2635h> <1> <1> <1> Remote Operations For DMD20 Signed value 0 to –2500 with implied decimal point; (0.00 to –25.00 dBm) (two’s compliment) For OM20 Signed value -2000 to -4500 with implied decimal point; (-20.00 to -45.00 dBm) For DMD20 Signed value 0 to –2500 with implied decimal point; (0.00 to –25.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> <1> <1> 1.5.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Descrambler Type <1> <1> <1> <1> <1> Spectrum Buffer Size msec Active Buffer Clock Source Buffer Clock Polarity Insert Mode <1> <30> T1E1 Frame Source Insert Map <1> Satellite Framing <1> <1> RX Test Pattern Map Summary To Backward Alarm <1> Force Alarm Test <1> Alarm 1 Mask <1> Alarm 2 Mask MN-DMDREMOTEOP Revision 9 Remote Operations 0 = None, 1 = IBS, 2 = V35 IESS, 3 = V35 CCITT, 4 = V35 EFDATA, 5 = V35 FAIRCHILD, 6 = OM-73,
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Alarm 3 Mask <1> Alarm 4 Mask <1> Common Alarm 1 Mask <1> Common Alarm 2 Mask <1> ESC Channel 1 Volume ESC Channel 2 Volume BER Exponent Rx Circuit ID Rx Terrestrial Loopback Rx Baseband Loopback Rx IF Loopback <1> <1> <11> <1> <1> <1> MN-DMDREMOTEOP Revision 9 Remote Operations Bit 0 = Rx L-Band Synthesizer Lock Bit 1 = Insert DSP Config Bit 2 = Buffer Clock PLL Lock Detect Bit 3 = Viterbi Decoder Lock Bit 4 = Sequential Decoder Lo
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Rx Interface Type <1> Insert Status Mask <1> <1> <1> <1> <1> Rx RS N Code Rx RS K Code Rx RS Depth External Clock Source Data Invert <1> Alarm 5 Mask <1> <1> <1> <1> BPSK Symbol Pairing ES Mode ES Type ES Baud <1> <1> <1> <1> <1> ES Data Bits IDR Overhead Type FM Orderwire Mode TMT Pattern Length EbNo Threshold <2> <1> <1> <1> Reacquisition Sweep Limit Terrestrial Streaming Terrestrial Framing Alarm 6 Mask <1> TPC De-Interleaver
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> SCC Control Ratio <4> <1> <1> SCC In band Rate Fast Acquisition Adjacent Carrier Type LBST LNB DC Voltage Alarm Lower Threshold LBST LNB DC Voltage Alarm Upper Threshold LBST LNB DC Current Alarm Lower Threshold LBST LNB DC Current Alarm Upper Threshold Number of Buffer Clock Sources First Buffer Clock Source Second Buffer Clock Source Third Buffer Clock Source Forth Buffer Clock Source Fifth Buffer Clock Source Asynchronous InBand Rate <2>
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Control Mode <1> <1> Revision Number Alarm 1 <1> Alarm 2 <1> Alarm 3 <1> Alarm 4 <1> Common Alarm 1 <1> Common Alarm 2 MN-DMDREMOTEOP Revision 9 Remote Operations Status Bytes (88 Bytes) 0 = Front Panel, 1 = Terminal, 2 = Computer, Note: DMD20 will always return 2 = Computer Decimal point implied Bit 0 = Receive FPGA/Processor Fault, 1 = Fail Bit 1 = Carrier Loss, 1 = Fail Bit 2 = Multiframe Sync Loss, 1 = Fail Bit 3 = Frame Sync
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Latched Alarm 1 <1> Latched Alarm 2 <1> Latched Alarm 3 <1> Latched Common Alarm 1 <1> Latched Common Alarm 2 <1> Backward Alarms <4> <4> <2> <2> Error Counter Test Error Counter Raw BER Mantissa Corrected BER Mantissa EbNo <2> MN-DMDREMOTEOP Revision 9 Remote Operations Bit 0 = Receive FPGA/Processor Fault Bit 1 = Carrier Loss Bit 2 = Multiframe Sync Loss Bit 3 = Frame Sync Loss Bit 4 = IBS BER Alarm Bit 5 = Satellite AIS Bit 6
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <4> <2> <1> <1> <1> Offset Frequency Test BER Mantissa Raw BER Exponent Corrected BER Exponent Test BER Exponent Offset Frequency Sign BER/EbNo Status <1> Buffer Percent Full <1> <1> Input Level Insert Status Fault <1> Online Flag <1> <1> Loss Flag Alarm 5 <1> Latched Alarm 4 <4> <1> Symbol Rate Latched Alarm 5 <1> Alarm 6 <1> <1> MN-DMDREMOTEOP Revision 9 Remote Operations Binary value, 1 Hz steps Bytes 1 - 2 = Binary value test
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Latched Alarm 6 <2> LBST LNB DC Current LBST LNB DC Voltage Ethernet Bridge PER Mantissa Ethernet Bridge PER Exponent Ethernet Bridge Packet Error Count Ethernet Bridge Packet Total Count Ethernet Bridge Port 1 Status <2> <2> <1> <4> <4> <1> <1> Ethernet Bridge Port 2 Status <1> Ethernet Bridge Port 3 Status <1> Ethernet Bridge Port 4 Status <1> Ethernet Bridge WAN Status <4> RFM AGC Voltage <1> RFM AGC Voltage Sign Carrier-in-Ca
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <4> Frequency <2> Sweep Delay <4> Data Rate <1> <1> Sweep Boundary Input Level Limit <2> <1> Strap Code Spectral Mask <1> Demodulation Type <1> Convolutional Decoder <1> <1> <1> <1> Reed Solomon Differential Decoder Descrambler Control Descrambler Type <1> <1> <1> <1> <1> Spectrum Buffer Size msec Active Buffer Clock Source Buffer Clock Polarity Insert Mode <1> <30> T1E1 Frame Source Insert Map MN-DMDREMOTEOP Revision 9 Remote O
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Satellite Framing <1> <1> RX Test Pattern Map Summary To Backward Alarm <1> Force Alarm Test <1> Alarm 1 Mask <1> Alarm 2 Mask <1> Alarm 3 Mask <1> Alarm 4 Mask <1> Common Alarm 1 Mask MN-DMDREMOTEOP Revision 9 Remote Operations 0 = No Framing, 1 = 96K IDR, 2 = 1/15 IBS, 3 = EF AUPC 1/15, 4 = DVB, 5 = EDMAC, 6 = SCC, 7 = 96K, 8 = Efficient D&I, 9 = Ebem 0 = None, 1 = 2047 (2^11-1), 2 = 2^15-1, 3 = 2^23-1 0 = None, 1 = BK1, 2 =
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Common Alarm 2 Mask <1> <1> <1> ESC Channel 1 Volume ESC Channel 2 Volume BER Exponent Rx Circuit ID Rx Terrestrial Loopback Rx Baseband Loopback Rx IF Loopback Rx Interface Type <1> Insert Status Mask <1> <1> <1> <1> <1> Rx RS N Code Rx RS K Code Rx RS Depth External Clock Source Data Invert <1> Alarm 5 Mask <1> <1> <1> BPSK Symbol Pairing ES Mode ES Type <1> <1> <11> <1> <1> MN-DMDREMOTEOP Revision 9 Remote Operations Bit 0 = T
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> ES Baud <1> <1> <1> <1> <1> ES Data Bits IDR Overhead Type FM Orderwire Mode TMT Pattern Length EbNo Threshold <2> <1> <1> <1> Reacquisition Sweep Limit Terrestrial Streaming Terrestrial Framing Alarm 6 Mask <1> <1> TPC De-Interleaver SCC Control Ratio <4> <1> <1> SCC In band Rate Fast Acquisition Adjacent Carrier Type LBST LNB DC Voltage Alarm Lower Threshold LBST LNB DC Voltage Alarm Upper Threshold LBST LNB DC Current Alarm Lower Thr
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <2> <1> <2> <2> <1> <1> <1> <1> <1> <4> RFM AGC Time Constant Carrier-in-Carrier Carrier-in-Carrier Minimum Search Delay Carrier-in-Carrier Maximum Search Delay Carrier-in-Carrier Frequency Offset Range EBEM overhead channel rate EBEM embedded channel EBEM ITA EBEM encryption EBEM Ethernet rate Opcode: <240Ch> Remote Operations 1 - 99999 in ms 0 = Disabled, 1 = Enabled 0 – 330 0 – 330 0 – 30 (KHz) 0 = Off, 1 = 8K, 2 = 16K, 3 = 24K, 4 = 32K
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Alarm 4 <1> Common Alarm 1 <1> Common Alarm 2 <1> Latched Alarm 1 <1> Latched Alarm 2 <1> Latched Alarm 3 MN-DMDREMOTEOP Revision 9 Remote Operations Bit 0 = Buffer Clock Activity Detect, 1 = Activity Bit 1 = External BNC Activity Detect, 1 = Activity Bit 2 = Rx Satellite Clock Activity Detect, 1 = Activity Bit 3 = Insert Clock Activity Detect, 1 = Activity Bit 4 = External Reference Activity Detect, 1 = Activity Bit 5 = High Stabi
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Latched Common Alarm 1 <1> Latched Common Alarm 2 <1> Backward Alarms <4> <4> <2> <2> <1> Error Counter Test Error Counter Raw BER Mantissa Corrected BER Mantissa EbNo Offset Frequency Test BER Mantissa Raw BER Exponent Corrected BER Exponent Test BER Exponent Offset Frequency Sign BER/EbNo Status <1> Buffer Percent Full <1> <1> Input Level Insert Status Fault <2> <4> <2> <1> <1> <1> <1> MN-DMDREMOTEOP Revision 9 Remote Operations
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Online Flag <1> <1> Loss Flag Alarm 5 <1> Latched Alarm 4 <4> <1> Symbol Rate Latched Alarm 5 <1> Alarm 6 <1> Latched Alarm 6 <2> LBST LNB DC Current LBST LNB DC Voltage Ethernet Bridge PER Mantissa Ethernet Bridge PER Exponent Ethernet Bridge Packet Error Count Ethernet Bridge Packet Total Count Ethernet Bridge Port 1 Status <2> <2> <1> <4> <4> <1> <1> Ethernet Bridge Port 2 Status <1> Ethernet Bridge Port 3 Status MN-DMDREMO
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Ethernet Bridge Port 4 Status <1> Ethernet Bridge WAN Status <4> RFM AGC Voltage <1> RFM AGC Voltage Sign Carrier-in-Carrier Run Time Delay Carrier-in-Carrier Run Time Frequency Offset Carrier-in-Carrier Ratio <4> <4> <2> Opcode: <2406h> Remote Operations 0 = Down, 1 = Unresolved, 2 = 10 Mbps Half, 3 = 100 Mbps Half, 4 = 10 Mbps Full, 5 = 100 Mbps Full, 6 = Port Not Used, 7 = 1000 Mbps Half, 8 = 1000 Mbps Full 0 = Down, 1 = Unresolve
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Latched Common Alarm 1 <1> Latched Common Alarm 2 <1> Latched Alarm 4 <1> Latched Alarm 5 <1> Latched Alarm 6 Opcode: <2409h> Remote Operations Bit 0 = -12V Alarm Bit 1 = +12V Alarm Bit 2 = +5V Alarm Bits 3 – 5 = Reserved Bit 6 = IF SYNTH Alarm Bit 7 = Spare 0 = Not Latched, 1 = Latched Bit 0 = TERR FPGA Config Bit 1 = CODEC FPGA Config Bit 2 = CODEC Device Config Bit 3 = TRANSEC Power Test Bit 4 = +1.5 V Rx Alarm Bit 5 = +1.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Alarm 3 <1> Alarm 4 <1> Insert Status Fault <1> Common Alarm 1 <1> Common Alarm 2 <1> Alarm 5 <1> Alarm 6 Opcode: <2452h> <1> <1> Remote Operations Bit 0 = Rx L-Band Synthesizer Lock, 1 = Lock Bit 1 = Insert DSP Config, 1 = Fail Bit 2 = Buffer Clock PLL Lock Detect, 1 = Lock Bit 3 = Viterbi Decoder Lock, 1 = Lock Bit 4 = Sequential Decoder Lock, 1 = Lock Bit 5 = Rx Test Pattern Lock, 1 = Lock Bit 6 = External Reference PLL Lock,
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> ES Baud <1> ES Data Bits Opcode: <2494h> <2> <1> <4> <4> <1> 0 =150, 1 = 300, 2 = 600, 3 = 1200, 4 = 2400, 5= 4800, 6 = 9600, 7 = 19200, 8 = 38400, 9 = 57600, 10 = 115200 0 = 7 Bits, 1 = 8 Bits Query Demodulator’s Ethernet Terrestrial Interface Packet Status Ethernet Bridge PER Mantissa Ethernet Bridge PER Exponent Ethernet Bridge Packet Error Count Ethernet Bridge Packet Total Count Ethernet Bridge Port 1 Status Query Response (16 Byte
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <4> Frequency <2> Sweep Delay <4> Data Rate <1> <1> Sweep Boundary Input Level Limit <2> <1> Strap Code Spectral Mask <1> Demodulation Type <1> Convolutional Decoder <1> <1> <1> <1> Reed Solomon Differential Decoder Descrambler Control Descrambler Type <1> <1> <1> <1> <1> Spectrum Buffer Size msec Active Buffer Clock Source Buffer Clock Polarity Insert Mode <1> <30> T1E1 Frame Source Insert Map MN-DMDREMOTEOP Revision 9 Remote O
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Satellite Framing <1> <1> RX Test Pattern Map Summary To Backward Alarm <1> Force Alarm Test <1> Alarm 1 Mask <1> Alarm 2 Mask <1> Alarm 3 Mask <1> Alarm 4 Mask <1> Common Alarm 1 Mask MN-DMDREMOTEOP Revision 9 Remote Operations 0 = No Framing, 1 = 96K IDR, 2 = 1/15 IBS, 3 = EF AUPC 1/15, 4 = DVB, 5 = EDMAC, 6 = SCC, 7 = 96K, 8 = Efficient D&I, 9 = Ebem 0 = None, 1 = 2047 (2^11-1), 2 = 2^15-1, 3 = 2^23-1 0 = None, 1 = BK1, 2 =
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Common Alarm 2 Mask <1> <1> <1> ESC Channel 1 Volume ESC Channel 2 Volume BER Exponent Rx Circuit ID Rx Terrestrial Loopback Rx Baseband Loopback Rx IF Loopback Rx Interface Type <1> Insert Status Mask <1> <1> <1> <1> <1> Rx RS N Code Rx RS K Code Rx RS Depth External Clock Source Data Invert <1> Alarm 5 Mask <1> <1> <1> BPSK Symbol Pairing ES Mode ES Type <1> <1> <11> <1> <1> MN-DMDREMOTEOP Revision 9 Remote Operations Bit 0 = T
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> ES Baud <1> <1> <1> <1> <1> ES Data Bits IDR Overhead Type FM Orderwire Mode TMT Pattern Length EbNo Threshold <2> <1> <1> <1> Reacquisition Sweep Limit Terrestrial Streaming Terrestrial Framing Alarm 6 Mask <1> <1> TPC De-Interleaver SCC Control Ratio <4> <1> <1> SCC In band Rate Fast Acquisition Adjacent Carrier Type LBST LNB DC Voltage Alarm Lower Threshold LBST LNB DC Voltage Alarm Upper Threshold LBST LNB DC Current Alarm Lower Thr
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <2> <1> <2> <2> <1> <1> <1> <1> <1> <4> RFM AGC Time Constant Carrier-in-Carrier Carrier-in-Carrier Minimum Search Delay Carrier-in-Carrier Maximum Search Delay Carrier-in-Carrier Frequency Offset Range EBEM overhead channel rate EBEM embedded channel EBEM ITA EBEM encryption EBEM Ethernet rate Opcode: <2A01h> <4> <4> <2> <1> <2> 0 = Off, 1 = 8K, 2 = 16K, 3 = 24K, 4 = 32K, 5 = 40K, 6 = 48K, 7 = 56K, 8 = 64K 0 = Off, 1 = On 0 = Disabled, 1
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Demodulation Type Opcode: <2A08h> <1> <1> <1> <1> <1> <1> Command Data (1 Byte) 0 = INTELSAT 0.35, 18 = MIL-188-165A, 20 = DVB 0.20, 25 = DVB 0.25, 35 = DVB 0.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Descrambler Type Opcode: <2A0Fh> <1> <1> <1> <1> <1> <1> <1> <1> <1> <1> <1> <1> Command Data (1 Byte) 0 = Normal, 1 = Inverted Command Data (1 Byte) 0 = Disabled, 1 = T1-D4, 2 = T1-ESF, 3 = PCM-30, 4 = PCM-30C, 5 = PCM-31, 6 = PCM-31C, 7 = SLC-96, 8 = T1 D4 S, 9 = T1 ESF S Command a Demodulator’s T1E1 Frame Source T1E1 Frame Source Opcode: <2A16h> 0 = SCTE, 1 = SCT, 2 = EXT BNC, 3 = RX SAT, 4 = EXT IDI, Each buffer clock source mu
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Satellite Framing Opcode: <2A17h> <1> <1> <1> <11> <1> <1> <1> Command Data (1 Byte) 0 = Disabled, 1 = Enabled Command a Demodulator's IF Loopback Rx IF Loopback Opcode: <2A1Fh> Command Data (1 Byte) 0 = Disabled, 1 = Enabled Command a Demodulator's Baseband Loopback Rx Baseband Loopback Opcode: <2A1Eh> Command Data (11 Bytes) 11 ASCII characters, null terminated Command a Demodulator's Terrestrial Loopback Rx Terrestrial Loo
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Rx Interface Type Opcode: <2A20h> Remote Operations 0 = G.703 Bal T1 AMI, 1 = G.703 Bal T1 B8ZS, 2 = G.703 B E1 HDB3, 3 = G.703 Bal T2 B6ZS, 4 = G.703 Unbal E1 HDB3, 5 = G.703 Unbal T2 B8ZS, 6 = G.703 Unbal E2 HDB3, 7 = RS422 Serial, 8 = V.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> <1> Rx RS N Code Rx RS K Code Rx RS Depth Opcode: <2A34h> <1> ES Mode ES Type ES Baud <1> ES Data Bits <1> Command Data (4 Bytes) 0 = Normal, 1 = Enhanced 0 = RS-232, 1 = RS-485 0 =150, 1 = 300, 2 = 600, 3 = 1200, 4 = 2400, 5= 4800, 6 = 9600, 7 = 19200, 8 = 38400, 9 = 57600, 10 = 115200 0 = 7 Bits, 1 = 8 Bits Command a Demodulator's Fast Acquisition Fast Acquisition Opcode: <2A37h> (No Parameters) Command Data (1 Byte) 0 = Disabl
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Opcode: <2403h> <1> <1> <1> <1> <1> Query Response (1 Byte) DMD20 Modulator = 20, DMD20 Demodulator = 21, DMD20 Modem = 22 Query a Modem's Control Mode Query Response (1 Byte) Modem control mode 0 = Front Panel, 1 = Terminal, 2 = Computer Note: DMD20 will always return 2 = Computer Opcode: <2407h> <1> Query a Modem's Identification Modem ID Opcode: <2404h> Remote Operations Query a Modem's Latched Alarms Query Response (11 Bytes) Mod
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Latched Common Alarm 1 <1> Latched Common Alarm 2 <1> Mod Latched Alarm 2 <1> Mod Latched Alarm 4 <1> Demod Latched Alarm 4 <1> Demod Latched Alarm 5 <1> Demod Latched Alarm 6 Opcode: <240Ah> Remote Operations Bit 0 = -12V Alarm Bit 1 = +12V Alarm Bit 2 = +5V Alarm Bits 3 – 5 = Reserved Bit 6 = IF SYNTH Alarm Bit 7 = Spare 0 = Not Latched, 1 = Latched Bit 0 = TERR FPGA Config Bit 1 = CODEC FPGA Config Bit 2 = CODEC Device Config
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Mod Alarm 1 <1> Mod Alarm 2 <1> Drop Status Fault <1> Demod Alarm 1 <1> Demod Alarm 2 <1> Demod Alarm 3 <1> Demod Alarm 4 MN-DMDREMOTEOP Revision 9 Remote Operations Bit 0 = Transmit FPGA/Processor Fault, 1 = Fail Bit 1 = Drop DSP, 1 = Fail Bit 2 = Transmit Symbol Clock PLL Lock, 1 = Lock Bit 3 = Reserved Bit 4 = IF/L-Band Synthesizer Lock, 1 = Lock Bits 5 & 6 = Reserved Bit 7 = Mod Summary Fault, 1 = Fail Bit 0 = Terrestrial Clo
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Insert Status Fault <1> Common Alarm 1 <1> Common Alarm 2 <1> Mod Backward Alarms <1> Mod Alarm 4 <1> Demod Alarm 5 <1> Demod Alarm 6 Opcode: <240Dh> <2> <2> <2> Remote Operations Bit 0 = Frame lock fault. 1 = Fail Bit 1 = Multiframe lock fault. Valid in E1 PCM-30 and PCM-30C, 1 = Fail Bit 2 = CRC lock fault. Valid in T1ESF, and E1 CRC enabled.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> <1> <1> <1> Raw BER Exponent Corrected BER Exponent BER/EbNo Status Input Level Reacquisition Is Ready Opcode: <240Eh> <1> <1> <1> <1> <1> <1> <1> <1> <1> <1> <1> <1> <1> <1> Query Time and Date Query Response (6 Bytes) 0 – 99 0 – 11 0 – 30 0 – 23 0 – 59 0 – 59 Query Modem Summary Faults Query Response (2 Bytes) Mod Summary Fault 0 = Pass, 1 = Fail Demod Summary 0 = Pass, 1 = Fail Fault Opcode: <2412h> <1> Query Response (3 Byt
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> <1> <4> Remote Operations Number Of Events Number of events to query, maximum events that can be queried is 3 Query Response (1, 77, 153 or 229 Bytes) Number Of Events Number of events in response: 0 = no events, there is no additional response data, 1 = 1 event, see event data for additional response data, 2 = 2 events, see event data for additional response data, event data will repeat once, 3 = 3 events, see event data for additional res
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Opcode: <2C00h> Command Drop & Insert Map Copy <1> From Map <1> To map Opcode: <2C01h> Command Data (2 Bytes) 0 = Drop active map, 1 = Insert active map, 2 = Drop edit map, 3 = Insert edit map, 4 - 11 = User map #1 through #8, 12 - 19 = ROM maps #1..
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Opcode: <2C09h> Remote Operations Clear Modem Common Latched Alarm 2 (No Data) Command Data (0 Bytes) Opcode: <2C0Ah> <1> Command Delete a Modem's Event Buffer Events to Delete Opcode: <2C0Bh> processor) Command Data (1 Byte) 1 = delete one event (deletes first event in buffer) , 2 = delete all events Command Soft Reset (No Data) (Stops petting the watch dog to restart the Command Data (0 Bytes) Opcode: <2490h> <8> <1> <1> <1> <1> <2> <1>
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Opcode: <2500h> <8> <1> <1> <1> <1> <2> <1> <8> <1> <8> <64> Command Data (12 Bytes) Hz 0 = High side, 1 = Low side 0 = Disabled, 1 = Enabled 0 = Disabled, 1 = Enabled 13, 16, 18, 24, 48 Command Downlink RF Command Data (8 Bytes) Hz Command BUC FSK Pass Thru Command Data (64 Bytes) BUC FSK Command Null Terminated ASCII string Data Opcode: <2E06h> <255> 0 = Disabled, 1 = Enabled Command Down Converter Configuration RF Opcode: <2F61h> 0
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Installed Features 1 <1> Installed Features 2 <1> Installed Features 3 <1> Installed Features 4 <1> Installed Features 5 MN-DMDREMOTEOP Revision 9 Remote Operations Query Response (6 Bytes) Bit 0 = 1 Mbps data rate Bit 1 = 5 Mbps data rate Bit 2 = 10 Mbps data rate Bit 3 = 20 Mbps data rate Bit 4 = Rx IF Band Bit 5 = Rx L Band Bit 6 = Tx IF Band Bit 7 = Tx L Band 0 = Feature Not Installed, 1 = Feature Installed Bit 0 = Enhanced ASYNC
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol <1> Installed Features 6 Remote Operations Bit 0 = CNC 10 Mbps Feature Bit 1 = CNC 15 Mbps Feature Bit 2 = CNC 20 Mbps Feature Bit 3 = CNC 25 Mbps Feature Bit 4 = CNC 30 Mbps Feature Bit 5 = CNC 40 Mbps Feature Bit 6 = CNC 52 Mbps Feature Bit 7 = EBEM 0 = Feature Not Installed, 1 = Feature Installed The features that are set refer to options purchased by the customer. These could be a subset of the overall physical capabilities of the product.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Remote Operations Notes: MN-DMDREMOTEOP Revision 9 1–86
Chapter 2.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol -- radyne SNMP (MIB) OBJECT IDENTIFIER ::= { enterprises 2591 } dmd20MibObjects radDmd20ModNVStatus radDmd20ModStatus OBJECT IDENTIFIER ::= { dmd20 1 } OBJECT IDENTIFIER ::= { dmd20MibObjects 1 } OBJECT IDENTIFIER ::= { dmd20MibObjects 2 } radDmd20DemodNVStatus OBJECT IDENTIFIER ::= { dmd20MibObjects 3 } radDmd20DemodStatus OBJECT IDENTIFIER ::= { dmd20MibObjects 4 } radDmd20CommonNVStatus OBJECT IDENTIFIER ::= { dmd20MibObjects 5 } radDmd20Com
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) RadVoltageLevel ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-1" STATUS current DESCRIPTION "Voltage level in tenths of a volt." SYNTAX INTEGER (0..550) RadCurrentLevel ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-3" STATUS current DESCRIPTION "Current level in milliamps." SYNTAX INTEGER (0..8000) ControlType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents a boolean control value.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) DISPLAY-HINT "d-2" STATUS current DESCRIPTION "EbNo alarm threshold. There is an implied decimal point." SYNTAX INTEGER (0..990) FirmwareNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "15a" STATUS current DESCRIPTION "This is the modem firmware name.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) ::= { radDmd20ModNVStatus 1 } radDmd20TxNetworkSpec OBJECT-TYPE SYNTAX INTEGER { closedNet(1), idr(2), ibs(3), dropInsert(4), dvbSat(5), milStd188pt165A(6), rfm(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the modulator's mode of operation. The mode sets a number of parameters within the modulator to meet a set of specifications. The purpose is to eliminate additional commands and compatibility problems.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) DESCRIPTION "Selects the modulator strap code. This is a quick set key that configures many of the modem parameters. When a strap code is entered, the modulator is automatically configured for the corresponding data rate, overhead, code rate, framing, scrambler type, and modulation.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) framingScc(7), framing96k(8), framingEfficientDnI(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects framing type.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) disable(1), t1d4(2), t1esf(3), pcm30(4), pcm30c(5), pcm31(6), pcm31c(7), slc96(8), t1d4s(9), t1esfs(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the modulator drop mode. SLC-96 is not yet implemented and is reserved for future use." ::= { radDmd20ModNVStatus 13 } radDmd20TxDropMap OBJECT-TYPE SYNTAX OCTET STRING (SIZE (32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the modulator drop map.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) internal(1), scr(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the Sct clock source to be internal or Scr. The Scr selection is used for loop timing.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) edmac(12), tpcIbs(13), tpcEdmac(14), v35Comstream(15) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects scrambler type. The reserved settings are unimplemented and are set aside for future use." ::= { radDmd20ModNVStatus 21 } radDmd20TxDifferentialEncoder OBJECT-TYPE SYNTAX ControlType MAX-ACCESS read-write STATUS current DESCRIPTION "Turns the differential encoder off and on.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) ::= { radDmd20ModNVStatus 26 } radDmd20TxTerrInterfaceType OBJECT-TYPE SYNTAX INTEGER { g703BT1Ami(1), g703BT1B8zs(2), g703BE1(3), g703BT2(4), g703UE1(5), g703UT2(6), g703UE2(7), rs422(8), v35(9), rs232(10), hssi(11), asi(12), aasi(13), m2p(14), dvb(15), ethernetBridge(25), milStd188pt114A(26), rs423(27), g703UT3(32), g703UE3(33), sts1Unbal(34) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the various interface types.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20TxAupcLocalCarrierLossAction OBJECT-TYPE SYNTAX INTEGER { hold(1), nominal(2), maximum(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects what action to take at the local site if the carrier is lost while using AUPC. This applies only if AUPC option is enabled.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) ::= { radDmd20ModNVStatus 33 } radDmd20TxAupcRemoteTestPattern OBJECT-TYPE SYNTAX ControlType MAX-ACCESS read-write STATUS current DESCRIPTION "Disables/Enables the remote site test pattern. This applies only if AUPC option is enabled." ::= { radDmd20ModNVStatus 34 } radDmd20TxAupcTargetEbnoDbX100 OBJECT-TYPE SYNTAX INTEGER (400..2000) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the AUPC EbNo.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) STATUS current DESCRIPTION "Enables test pattern operation." ::= { radDmd20ModNVStatus 39 } radDmd20TxCircuitName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (11)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides entry of Tx circuit identifier. Circuits can be given up to 11 character alphanumeric identity such as LINK1.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) dataAISRequest(4), yellowAlarm(5), ibsPromptAlarm(6), ibsServiceAlarm(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Tx forced backward alarms: Bit 0 = IDR and IBS backward alarm 1 Bit 1 = IDR only backward alarm 2 Bit 2 = IDR only backward alarm 3 Bit 3 = IDR only backward alarm 4 Bit 4 = Tx data AIS request Bit 5 = Yellow alarm (D&I mode) 0=Do not force, 1=Force alarm" ::= { radDmd20ModNVStatus 43 } radDmd20TxDropStatusMask OBJ
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) milStd188pt165A(4), dvbSat020(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the transmit spectral mask and roll off.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) A ReedSolomon N code is the codeword length or block length. It is the sum of message and check symbols. N = K + R. ReedSolomon K code is the message length or user data. It is the number of user data symbols in one message block. Message length is K = N - R." ::= { radDmd20ModNVStatus 50 } radDmd20TxIfecInterleaver OBJECT-TYPE SYNTAX ControlType MAX-ACCESS read-write STATUS current DESCRIPTION "Disables/Enables the IFEC interleaver.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) DESCRIPTION "Selects the baud rate for enhanced async. This applies only if the async mode is set to enhanced." ::= { radDmd20ModNVStatus 54 } radDmd20TxEsBitsPerChar OBJECT-TYPE SYNTAX INTEGER { seven(1), eight(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the data bits setting for enhanced async. This applies only if the async mode is set to enhanced.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Selects Sct clock polarity.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20TxEthQosQue OBJECT-TYPE SYNTAX INTEGER { fairWeighted(1), strictPriority(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects Quality of Service Type queueing method." ::= { radDmd20ModNVStatus 64 } -- ----------------------------------------------------------------------------------------------------- Dmd20 modulator status information.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) terrCrcFault(2), bit3Reserved(3), bit4Reserved(4), bit5Reserved(5), bit6Reserved(6), bit7Reserved(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field. On startup, the agent initializes this to the value '00000000'B.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) SYNTAX BITS { terrClockActivity(0), internalClockActivity(1), satClockActivity(2), dataActivity(3), dataAISFault(4), clockFallbackFault(5), dvbFrameFault(6), tpcConflict(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field. On startup, the agent initializes this to the value '00000000'B. 0 = Pass, 1 = Fail" ::= { radDmd20ModStatus 6 } radDmd20TxSymbolRateHz OBJECT-TYPE SYNTAX Unsigned32 (9600..
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) STATUS current DESCRIPTION "A bit field. On startup, the agent initializes this to the value '00000000'B. Activity/Lock: 1 = Pass, 0 = Fail Alarm/Fault: 0 = Pass, 1 = Fail" ::= { radDmd20ModStatus 9 } -- ----------------------------------------------------------------------------------------------------- Dmd20 demodulator non-volatile status information.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) configures many of the modem parameters. When a strap code is entered, the demodulator is automatically configured for the corresponding data rate, overhead, code rate, framing, descrambler type, and demodulation.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) framingEfficientDnI(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects framing type.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) t1esf(3), pcm30(4), pcm30c(5), pcm31(6), pcm31c(7), slc96(8), t1d4s(9), t1esfs(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the demodulator insert mode. SLC-96 is not yet implemented and is reserved for future use." ::= { radDmd20DemodNVStatus 11 } radDmd20RxInsertMap OBJECT-TYPE SYNTAX OCTET STRING (SIZE (32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the demodulator insert map.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) none(1), terrestrial(2), baseband(3), terrestrialAndBaseband(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects data polarity" ::= { radDmd20DemodNVStatus 16 } radDmd20RxSpectrum OBJECT-TYPE SYNTAX INTEGER { normal(1), inverted(2), autoDetect(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Inverts the direction of rotation for PSK demodulation.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20RxDifferentialDecoder OBJECT-TYPE SYNTAX ControlType MAX-ACCESS read-write STATUS current DESCRIPTION "Disables/enables differential decoder" ::= { radDmd20DemodNVStatus 20 } radDmd20RxBpskSymbolPairingSwap OBJECT-TYPE SYNTAX INTEGER { normal(1), swapped(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects symbol pairing.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20RxEscOverheadType OBJECT-TYPE SYNTAX INTEGER { voice(1), data(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects IDR overhead type. This applies only if an IDR or IBS interface card is installed and the receive mode is set to IDR mode. If not ignore.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) DESCRIPTION "Selects the various interface types." ::= { radDmd20DemodNVStatus 29 } radDmd20RxEsEnhancedEnable OBJECT-TYPE SYNTAX INTEGER { normal(1), enhanced(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the async mode. Enhanced mode is only valid in Closed Net mode.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) "Selects the data bits setting for enhanced async. This applies only if the async mode is set to enhanced." ::= { radDmd20DemodNVStatus 33 } radDmd20RxTestPattern OBJECT-TYPE SYNTAX INTEGER { normal(1), test2047(2), testPattern2To15Minus1(3), testPattern2To23Minus1(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables test pattern operation.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20RxAlarms2Mask OBJECT-TYPE SYNTAX BITS { bufferUnderflow(0), bufferOverflow(1), bufferNearEmpty(2), bufferNearFull(3), ofecDecoderFault(4), deinterleaverFault(5), uncorrectedWordFault(6), summaryFault(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm mask: 0 = Mask, 1 = Allow" ::= { radDmd20DemodNVStatus 38 } radDmd20RxAlarms3Mask OBJECT-TYPE SYNTAX BITS { lBandSynthesizerLock(0), insertDspFault(1), bufferClockLock(2),
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) SYNTAX BITS { trellisDecoderLock(0), ifecLockFault(1), insertSignalingFault(2), tpcConflict(3), bit4Reserved(4), bit5Reserved(5), dvbFrameFault(6), bit7Reserved(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm mask: 0 = Mask, 1 = Allow" ::= { radDmd20DemodNVStatus 41 } radDmd20RxInsertStatusMask OBJECT-TYPE SYNTAX BITS { terrFrameFault(0), terrMultiframeFault(1), terrCrcFault(2), bit3Reserved(3), bit4Reserved(4), bit5Reserved
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) ::= { radDmd20DemodNVStatus 44 } radDmd20RxAlarms6Mask OBJECT-TYPE SYNTAX BITS { lnbCurrentFault(0), lnbVoltageFault(1), ethernetWanMajorAlarm(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm mask: 0 = Mask, 1 = Allow" ::= { radDmd20DemodNVStatus 45 } radDmd20RxCarrierReacqRange OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Reacquisition range is -/+ selected value.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) ::= { radDmd20DemodNVStatus 49 } radDmd20RxEbnoAlarmThreshold OBJECT-TYPE SYNTAX EbnoAlarmThresholdType MAX-ACCESS read-write STATUS current DESCRIPTION "EbNo alarm threshold. There is an implied decimal point." ::= { radDmd20DemodNVStatus 50 } radDmd20RxBufferReset OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "Any write to this object resets the buffer.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) ::= { radDmd20DemodNVStatus 55 } radDmd20RxSpectralMask OBJECT-TYPE SYNTAX INTEGER { intelsat035(1), dvbSat025(2), dvbSat035(3), milStd188pt165A(4), dvbSat020(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the receive spectral mask and roll off.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20RxBufferClockSource2 OBJECT-TYPE SYNTAX BufferClockSourceType MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the second Rx Buffer Clock Source, e.g. the first fallback Each radDmd20RxBufferClockSource should be unique " ::= { radDmd20DemodNVStatus 61 } radDmd20RxBufferClockSource3 OBJECT-TYPE SYNTAX BufferClockSourceType MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the third Rx Buffer Clock Source, e.g.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects Efficient D&I format Inband Rate.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) bufferUnderflow(0), bufferOverflow(1), bufferNearEmpty(2), bufferNearFull(3), ofecDecoderFault(4), deinterleaverFault(5), uncorrectedWordFault(6), summaryFault(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field. On startup, the agent initializes this to the value '00000000'B.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) SYNTAX BITS { trellisDecoderLock(0), ifecLockFault(1), insertSignalingFault(2), tpcConflict(3), bit4Reserved(4), bit5Reserved(5), dvbFrameFault(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field. On startup, the agent initializes this to the value '00000000'B.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) SYNTAX BITS { rxFpgaFault(0), carrierFault(1), multiframeSyncFault(2), frameSyncFault(3), ibsBerFault(4), satelliteAisFault(5), dataActivity(6), agcLevelFault(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field. On startup, the agent initializes this to the value '00000000'B.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) externalBncActivity(1), satelliteClockActivity(2), externalIdiClockActivity(3), externalReferenceActivity(4), hsReferenceActivity(5), bit6Reserved(6), ebnoFault(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field. On startup, the agent initializes this to the value '00000000'B.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20RxBufferLevel OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Pleisiochronous buffer percent full status. Unsigned binary value in 1% steps.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) ethernetWanMajorAlarm(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field. On startup, the agent initializes this to the value '00000000'B. Activity/Lock: 1 = Pass, 0 = Fail Alarm/Fault: 0 = Pass, 1 = Fail" ::= { radDmd20DemodStatus 21 } radDmd20RxLatchedAlarms6 OBJECT-TYPE SYNTAX BITS { lnbCurrentFault(0), lnbVoltageFault(1), ethernetWanMajorAlarm(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20RxEthJs2PortStatus OBJECT-TYPE SYNTAX INTEGER { down(1), unresolved(2), halfDuplex10mbs(3), halfDuplex100mbs(4), fullDuplex10mbs(5), fullDuplex100mbs(6), portNotUsed(7), halfDuplex1000mbs(8), fullDuplex1000mbs(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet bridge JS 2 port status.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) SYNTAX INTEGER { down(1), unresolved(2), halfDuplex10mbs(3), halfDuplex100mbs(4), fullDuplex10mbs(5), fullDuplex100mbs(6), portNotUsed(7), halfDuplex1000mbs(8), fullDuplex1000mbs(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet bridge WAN Status.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20RxAgcVoltage OBJECT-TYPE SYNTAX INTEGER (0..990) MAX-ACCESS read-only STATUS current DESCRIPTION "Rx Agc Voltage Level in Volts. There is an implied decimal point. A value of 450 corresponds to 4.50V" ::= { radDmd20DemodStatus 35 } -- ----------------------------------------------------------------------------------------------------- Dmd20 common non-volatile status information.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) "Alarm mask: 0 = Mask, 1 = Allow" ::= { radDmd20CommonNVStatus 4 } radDmd20CommonAlarms2Mask OBJECT-TYPE SYNTAX BITS { terrFpgaFault(0), codecFpgaFault(1), codecDeviceFault(2), bit3Reserved(3), dmdPos1p5VoltAlarm(3), bit4Reserved(4), modPos1p5VoltAlarm(5), pos3p3VoltAlarm(6), pos20VoltAlarm(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm mask: 0 = Mask, 1 = Allow" ::= { radDmd20CommonNVStatus 5 } radDmd20CommonCarrierType OB
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) SYNTAX INTEGER { computer(1), terminal(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects wheather the serial remote control is terminal or computer.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) baud1200(4), baud2400(5), baud4800(6), baud9600(7), baud19200(8), baud38400(9), baud57600(10), baud115200(11) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects remote port Baud Rate." ::= { radDmd20CommonNVStatus 12 } radDmd20CommonRemoteInterface OBJECT-TYPE SYNTAX INTEGER { rs232(1), rs485(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects remote line interface type.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) -- ----------------------------------------------------------------------------------------------------- Dmd20 common status information. radDmd20CommonAlarms1 OBJECT-TYPE SYNTAX BITS { minus12VoltAlarm(0), plus12VoltAlarm(1), plus5VoltAlarm(2), bit3Reserved(3), bit4Reserved(4), bit5Reserved(5), ifLoSynthesizerFault(6), bit7Reserved(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) "A bit field. On startup, the agent initializes this to the value '00000000'B. 0 = Pass, 1 = Fail" ::= { radDmd20CommonStatus 3 } radDmd20CommonLatchedAlarms2 OBJECT-TYPE SYNTAX BITS { terrFpgaFault(0), codecFpgaFault(1), codecDeviceFault(2), dmdPos1p5VoltAlarm (3), bit4Reserved(4), modPos1p5VoltAlarm(5), pos3p3VoltAlarm(6), pos20VoltAlarm(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) -- Include Prefix for compatibility with SNMPv1 traps and procedures -- employed by multi-lingual and proxy forwarding systems radDmd20TrapPrefix OBJECT IDENTIFIER ::= { radDmd20Traps 0 } radDmd20TxMajorAlarmTrap NOTIFICATION-TYPE OBJECTS { radDmd20TxAlarms1 } STATUS current DESCRIPTION "Transmit major alarm trap.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) -- DMD20 LBST -- Dmd20 Mod Lbst nonvolatile status information. radDmd20LbstTxUplinkFrequencyHz OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "Selects RF frequency in Hz steps. 2GHz to 99 GHz." ::= { radDmd20ModLbstNVStatus 1 } radDmd20LbstTxLoFrequencyHz OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "Selects local oscillator frequency in Hz steps. 2GHz to 99 GHz.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) MAX-ACCESS read-write STATUS current DESCRIPTION "BUC Hi voltage alarm threshold. There is an implied decimal point." ::= { radDmd20ModLbstNVStatus 7 } radDmd20LbstTxCurrentLowerThreshold OBJECT-TYPE SYNTAX RadCurrentLevel MAX-ACCESS read-write STATUS current DESCRIPTION "BUC Low current draw alarm threshold. There is an implied decimal point.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) is dependent upon the protocol selected.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) DESCRIPTION "Summary Status value provided by the BUC across the Fsk interface" ::= { radDmd20ModLbstStatus 5 } radDmd20BucTemperature OBJECT-TYPE SYNTAX RadTemperature MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature, in degrees C, as reported by the BUC across the Fsk interface. There is an implied decimal point. For example, a value of 300 represents a temperature of 30.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) ::= { radDmd20DemodLbstNVStatus 2 } radDmd20LbstRxSideBand OBJECT-TYPE SYNTAX INTEGER { highSide(1), lowSide(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Oscillator side band select." ::= { radDmd20DemodLbstNVStatus 3 } radDmd20LbstRx10MhzReferenceEnable OBJECT-TYPE SYNTAX ControlType MAX-ACCESS read-write STATUS current DESCRIPTION "10 MHz LNB reference enable.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) ::= { radDmd20DemodLbstNVStatus 8 } radDmd20LbstRxCurrentLowerThreshold OBJECT-TYPE SYNTAX RadCurrentLevel MAX-ACCESS read-write STATUS current DESCRIPTION "LNB Low current draw alarm threshold. There is an implied decimal point." ::= { radDmd20DemodLbstNVStatus 9 } radDmd20LbstRxCurrentUpperThreshold OBJECT-TYPE SYNTAX RadCurrentLevel MAX-ACCESS read-write STATUS current DESCRIPTION "LNB Hi current draw alarm threshold.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20TxClockSource, radDmd20TxClockPolarity, radDmd20TxSctClockSource, radDmd20TxDataPolarity, radDmd20TxSpectrum, radDmd20TxScramblingEnable, radDmd20TxScramblingType, radDmd20TxDifferentialEncoder, radDmd20TxBpskSymbolPairingSwap, radDmd20TxEscOverheadType, radDmd20TxEsc1GaindBX100, radDmd20TxEsc2GaindBX100, radDmd20TxTerrInterfaceType, radDmd20TxAupcLocalMode, radDmd20TxAupcRemoteMode, radDmd20TxAupcLocalCarrierLossAction, radDmd20
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) OBJECTS { radDmd20TxAlarms1, radDmd20TxAlarms2, radDmd20TxDropStatus, radDmd20TxBackwardAlarms, radDmd20TxLatchedAlarms1, radDmd20TxLatchedAlarms2, radDmd20TxSymbolRateHz, radDmd20TxAlarms4, radDmd20TxLatchedAlarms4 } STATUS current DESCRIPTION "Modulator volatile status group.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20RxAlarms4Mask, radDmd20RxAlarms5Mask, radDmd20RxInsertStatusMask, radDmd20RxTerrestrialFraming, radDmd20RxTerrestrialStreaming, radDmd20RxAlarms6Mask, radDmd20RxCarrierReacqRange, radDmd20RxRsOfecRate, radDmd20RxIfecInterleaver, radDmd20RxCarrierSweepDelay, radDmd20RxEbnoAlarmThreshold, radDmd20RxBufferReset, radDmd20RxRestartTestPattern, radDmd20RxSccCtlRatio, radDmd20RxSccInbandRate, radDmd20RxFastAcquisition, radDmd20RxSpectra
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20RxEthPktErrorCount, radDmd20RxEthPktTotalCount, radDmd20RxEthJs1PortStatus, radDmd20RxEthJs2PortStatus, radDmd20RxEthJs3PortStatus, radDmd20RxEthJs4PortStatus, radDmd20RxEthWanStatus, radDmd20RxRawBerStatus, radDmd20RxCorrectedBerStatus, radDmd20RxTestPatternBerStatus, radDmd20RxAupcRemoteBerStatus, radDmd20RxCarrierFrequencyOffset, radDmd20RxAgcVoltage } STATUS current DESCRIPTION "Demodulator volatile status group.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) radDmd20NotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { radDmd20TxMajorAlarmTrap, radDmd20TxMinorAlarmTrap, radDmd20RxMajorAlarmTrap, radDmd20RxMinorAlarmTrap, radDmd20CommonAlarmTrap } STATUS current DESCRIPTION "Cold start trap and authentication failure trap are the two notifications which an SNMPv2 entity is required to implement. Major, minor, and common alarm traps are product specific.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) OBJECTS { radDmd20LbstRxDownlinkFrequencyHz, radDmd20LbstRxLoFrequencyHz, radDmd20LbstRxSideBand, radDmd20LbstRx10MhzReferenceEnable, radDmd20LbstRxVoltageEnable, radDmd20LbstRxVoltageSelect, radDmd20LbstRxVoltageLowerThreshold, radDmd20LbstRxVoltageUpperThreshold, radDmd20LbstRxCurrentLowerThreshold, radDmd20LbstRxCurrentUpperThreshold } STATUS current DESCRIPTION "Demod Lbst nonvolatile status group.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP (MIB) Notes: MN-DMDREMOTEOP Revision 9 2–66
Chapter 3. Web Browser 3.1 Web Browser User Interfaces The Web Browser user interface is available on the DMD20, DMD20LBST, DMD50, DMD2050 and OM20. The Web Browser interface can be accessed through the RJ45, SNMP port located on the unit. Instructions on how to configure the interface for this application can be accessed from the product manual. This section is primarily designed to illustrate all the menus associated with the Web Browser and will not give full descriptions or details of these features.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol 3.2 Web Browser Configuring Your PC An example of the GUI layout is shown in Figure 3-1, showing the location and labeling of the Interface. The graphical user interface is designed to replicate the front panel. For users familiar with the front panel interface adjusting to the GUI interface should be seamless.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol 6 Product Information Contact Information Web Browser Access to technical trouble-shooting, product options and specifications is accomplished by selecting one and clicking on that function. Contacting Radyne via Email is possible by clicking on “Contact Us”. 3.2.1 LED Indicators Twelve LEDs on the GUI Interface (Refer to Table 3-2) indicate the status of the modems operation. The LED colors maintain a consistent meaning.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol 3.3 Web Browser GUI Screen Menus There are four main menus displayed on the Introduction screen upon startup of the web browser. This screen will give a brief overview of the product and contains no configurable items.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser 3.3.1 Introduction Menu This menu will first appear when starting up the web browser. This page lists the general features of the unit, and lists a brief description of the unit. Notice on the bottom of the page that there are selections for technical Specifications, Product Options, Troubleshooting, About Us, and Contact us. Access these areas for further detailed description of the selection.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol 3.3.1.1 Web Browser Login Screen Upon initially accessing either the Setup, Monitor & Control, or Administration configuration menu tabs a login prompt will appear. In order to gain access to any of the configuration menus, log in with the correct user name and password. (The factory default login name is “admin” and the default password is “admin”). For further information on setting user profiles see Section 3.3.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser 3.3.2 Password Setup The Password Access Menu allows for multiple operators to be allowed access to the system. User access priorities can be set be completing the fields in the Access menu below. Access Menu Figure 3-4 Access Menu Edit User {USER 1, USER 2, USER 3} Allows the operator to assign the applicable user group. User Access Group {Guest, Operator, Admin} Allows the operator to assign the applicable user Access Level group.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Preferences Menu Figure 3-5 Modem Preferences Menu User Confirmation: MN-DMDREMOTEOP Revision 9 {DISABLED, ENABLED} The user information preference allows the user to force/disable confirmation of all changes through the web interface. This does not override bandwidth confirmations. However, these are always enabled.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser 3.3.3 IP and Application Administration The IP and Application menu provides instructions on how to configure the modem, applications and PC. Modem Addressing Figure 3-6 Modem Addressing Server Boot Mode: {DEFAULT, NON-VOL, BOOTP, IP TEST} Default: All of the following parameters as shown in Table 3-3 through 3-7 will be set and will not change until the boot mode is changed. IP IPMASK: 255.000.000.000 MODEM IPADDR: 010.000.000.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol SNMP SNMP VERSION: V1 & V2 TRAP VERSION: V1 AUTHORIZATION: TRAPS OFF RD COMMUNITY: PUBLIC RDWR COMMUNITY: PUBLIC USER 1 Viewer-md5 ACCESS GROUP VIEWER AUTH PASSWORD Viewer PRIV PASSWORD Viewer AUTHENTICATION MD5 PRIVACY DES USER 2 Viewer-sha ACCESS GROUP VIEWER AUTH PASSWORD Viewer PRIV PASSWORD Viewer AUTHENTICATION SHA PRIVACY DES Web Browser USER 3 Oper-md5 ACCESS GROUP OPER AUTH PASSWORD Oper PRIV PASSWORD Oper AUTHENTICATION MD5 PRIVACY DES
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser NON-VOL: Stores and uses IP Mask and addresses as provided by the user. BOOTP: At boot time, use Bootp Protocol to get names, masks, and IP Addresses of the modem, router, and server. IP TEST: The IP Test boot mode has a similar behavior to the default boot mode. The Terminal, IP, SNMP, FTP and Web parameters changed by the default setting will also be reset by the IP Test boot mode.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Configuring Applications Figure 3-7 Configuring Applications SNMP Setup: SNMP Version: {V1 & 2, V3} Default = V1 & V2 Trap Version: {V1 & 2} Default = V1 Authorization: {TRAPS ON, TRAPS OFF} Default = TRAPS OFF Read Community: {Public} Default Read/Write Community: {Public} Default FTP Setup: UserID: User Password: Password MN-DMDREMOTEOP Revision 9 3–12
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Configuring The PC Figure 3-8 Configuring the PC MN-DMDREMOTEOP Revision 9 3–13
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser 3.3.4 Monitor and Control Menu Under this menu, all modem functions that are monitored and/or controlled are accessible. To access the M&C sub menu options drag the cursor across the gel-tabs. Note that as the cursor passes over a tab it is highlighted and a menu drops below the tab. Stop on the desired tab move the cursor down and then across to the desired function.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Transmit / Data Menu Figure 3-10 Transmit / Data Menu Transmit / Reed-Solomon Menu Figure 3-11 Transmit / Reed-Solomon Menu MN-DMDREMOTEOP Revision 9 3–15
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Transmit / ODU-BUC Menu Figure 3-12 Transmit / ODU-BUC Menu Transmit / AUPC Menu Figure 3-13 Transmit / AUPC Menu This menu is only available for the DMD20LBST and the OM20.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol 3.3.4.2 Web Browser Receive Menu The Receive menu contains sub menus; General | IF, Data, Reed Solomon and ODU-LNB. Receive General / IF Menu Figure 3-14 Receive General / IF Menu The Downlink Frequency (MHz) menu is only available with the DMD20LBST and the OM20.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Receive / Data Menu Figure 3-15 Receive / Data Menu Receive / Reed-Solomon Menu Figure 3-16 Receive / Reed-Solomon Menu MN-DMDREMOTEOP Revision 9 3–18
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Receive / ODU-BUC Menu Figure 3-17 Receive / ODU-LNB Menu This menu is only available with the DMD20LBST and the OM20.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Receive / CNC Menu Figure 3-18 Receive / CNC Menu This menu is not available with the OM20.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol 3.3.4.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Interface / RX Setup Menu Figure 3-20 Interface / RX Setup Menu Interface / General Menu Figure 3-21 Interface / General Menu MN-DMDREMOTEOP Revision 9 3–22
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol 3.3.4.4 Web Browser Monitor / Voltages Menu Monitor / General | Voltages Figure 3-22 Monitor / Voltages Menu LNB and BUC options are only available on the DMD20LBST and the OM20.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Monitor / Ethernet Link Status Figure 3-23 Monitor / Ethernet Link Status Ethernet Link Status Options are only available if a Ethernet Option Card is installed into the unit.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Monitor / Event Menu Figure 3-24 Monitor / Event Menu Delete All: Cleans the entire event buffer. Event Type: I Informational Y Yellow alarm. Indicates a transmit or receive warning condition. R Red alarm. Indicates a transmit or receive failure, losing traffic. The Event Buffer may be sorted by warning level, time, date, or event description. This feature may be used to further investigate event occurances.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Monitor / CNC Figure 3-25 Monitor / Carrier in Carrier Menu This menu is not available with the OM20.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol 3.3.4.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Alarms / Receive Menu Figure 3-27 Alarms / Receive Menu Reset Lathed Alarms: Clicking on this button will reset (Clear) all Latched Alarms Force Alarm Test: Clicking on this button will force alarms.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Alarms / Backward Menu Figure 3-29 Alarms / Backward Menu MN-DMDREMOTEOP Revision 9 3–29
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol 3.3.4.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser System / Features Menu Figure 3-32 System / Features The Web Browser menu allows viewing of actively enabled features. Each feature displays a series of symbols that describe feature status. The following symbols indicate: Installed No hardware available. Requires hardware for upgrade. Feature is in Demo Mode and will expire.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol 3.3.4.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Test I/Q Plot Figure 3-34 Test I/Q Plot Test Spectrum Plot Figure 3-35 Test Spectrum Plot MN-DMDREMOTEOP Revision 9 3–33
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Web Browser Notes: MN-DMDREMOTEOP Revision 9 3–34
Chapter 4. Protocol Terminal Menus 4.1 Terminal Mode Control The Terminal Mode Control allows the use of an external terminal or computer to monitor and control the modem from a full screen interactive presentation operated by the modem itself. No external software is required other than VT-100 Terminal Emulation Software (e.g. “Procomm” for a computer when used as a terminal. The Control Port is normally used as an RS–232 Connection to the terminal device.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus A “break” signal on the communications line, pressing “ESC” on the terminal or Power On of the modem will initiate full screen terminal mode printing and redraw the full screen. The Terminal Mode displays the present status of all user parameters controlled and read by the processor, and offers a menu allowing change to any controlled parameter.
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus 1. Modem configuration can be monitored and controlled via a full screen presentation of current settings and status. The Key redraws the entire screen and aborts input any time. The Spacebar refreshes the status area and is used to scroll through selection when in user input mode. 2. To modify an item, the user simply presses its terminal selection followed by .
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus The charts that follow identify the Menu Control’s Sub-Menus: MN-DMDREMOTEOP Revision 9 4–4
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus Modulator Control Screen: Demodulator Control Screen: MN-DMDREMOTEOP Revision 9 4–5
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus Modulator Drop Control Screen: Demodulator Insert Control Screen: MN-DMDREMOTEOP Revision 9 4–6
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus Modulator Alarm Status Screen: Demodulator Alarm Status Screen: MN-DMDREMOTEOP Revision 9 4–7
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus AUPC Control Screen: ASYNC Control Screen: MN-DMDREMOTEOP Revision 9 4–8
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus LBST Control: Ethernet Control Screen: MN-DMDREMOTEOP Revision 9 4–9
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus System Configuration Screen: TCP/IP Control Screen: MN-DMDREMOTEOP Revision 9 4–10
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus SNMP Control Screen: FTP Control Screen: MN-DMDREMOTEOP Revision 9 4–11
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus Web Control: Features Screen: MN-DMDREMOTEOP Revision 9 4–12
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus Tests / Loopbacks Screen: Event Log Screen: MN-DMDREMOTEOP Revision 9 4–13
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol Protocol Terminal Menus Notes: MN-DMDREMOTEOP Revision 9 4–14
2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX