Operating instructions

RCS20 M:N Redundancy Switch Installation
TM056 - Rev. 2.3 2-13
2.6.6 J6 - ES/ES
The connector pinouts for J6, the 9-Pin Earth-Station-to-Earth-Station asynchronous data connector
are shown below.
Table 2-7. J6 - ES/ES - 9-Pin ‘D’ Female
Pin No. Signal Description Direction
1 GND Ground None
2 RXD-232 Receive Data RS232 Output
3 TXD-232 Transmit Data RS232 Input
4 TXD-B Transmit Data RS485 (+) Input
5 TXD-A Transmit Data RS485 (-) Input
6 NC No Connection None
7 NC No Connection None
8 RXD-B Receive Data B RS485 (+) Output
9 RXD-A Receive Data A RS485 (-) Output
2.6.7 J7 ESC Alarm Interface
The connector pinouts for J7, the 25-Pin ESC Alarm Interface are shown below.
Table 28. J7 - ESC Alarm Interface - 25-Pin Female ‘D’
Pin Number Signal Description Direction
1 GND Ground None
2 ESCBWO 1 NO Backward Alarm Out-1 NO None
3 NC No Connection None
4 ESCBWO 1 NO Backward Alarm Out-2 NO None
5 NC No Connection None
6 ESCBWO 4 NO Backward Alarm Out-4 NO None
7 GND Ground None
8 ESCBWO 4 NO Backward Alarm Out-4 NO None
9 NC No Connect None
10 ESCBWI 2 Backward Alarm In 2 Input
11 ESCBWI 4 Backward Alarm In 4 Input
12 NC No Connect None
13 NC No Connect None