Operating instructions
Appendix B RCS20 M:N Redundancy Switch
B-8 TM056 – Rev. 2.3
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the network specification."
::= { radSNMP_Mod_NV_Status 32 }
radInterleaver OBJECT-TYPE
SYNTAX INTEGER {
enable(0),
disable(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the interleaver."
::= { radSNMP_Mod_NV_Status 33 }
radOutClockSelection OBJECT-TYPE
SYNTAX INTEGER {
scte(0),
sct(1),
none(2),
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the source of clock output from the Terrestrial Interface.
See the Clock Source Selection Matrix."
::= { radSNMP_Mod_NV_Status 34 }
radLastRateControl OBJECT-TYPE
SYNTAX INTEGER {
symbol(0),
data(1),
auto(2)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Allows the modulator to behave with symbol rate or data rate
precedence based on the selection.
See rate control notes."
::= { radSNMP_Mod_NV_Status 35 }
-----------------------------------------------------------------------------
-- Status information out of Radyne specific MIB
radMajorAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"Major Alarm status:
A bit field. 0 = PASS, 1 = FAIL
Bit 1 = Oversample Clock PLL Lock
Bit 2 = FPGA Configuration Error
Bit 3 = Synthesis Clock PLL Lock
Bit 4 = External Reference PLL Lock
"