Operating instructions
RCS20 M:N Redundancy Switch Appendix B
TM056 – Rev. 2.3 B-5
::= { radSNMP_Mod_NV_Status 17 }
radModulationType OBJECT-TYPE
SYNTAX INTEGER {
qpsk(0),
bpsk(1),
psk8(2),
qam16(3)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the modulation type.
Note: Changing modulation type will affect the symbol rate and data rate.
See note at the end of this section."
::= { radSNMP_Mod_NV_Status 18}
radFraming OBJECT-TYPE
SYNTAX INTEGER {
dvb(0)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Selects framing type.
Reserved"
::= { radSNMP_Mod_NV_Status 19 }
radReedsolomon OBJECT-TYPE
SYNTAX INTEGER {
disable(0)
enable(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables the ReedSolomon encoder. Reserved"
::= { radSNMP_Mod_NV_Status 20 }
radScramblerControl OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables scrambler operation"
::= { radSNMP_Mod_NV_Status 21 }
radScramblerType OBJECT-TYPE
SYNTAX INTEGER {
dvb(0)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Selects scrambler type.
Not implemented"
::= { radSNMP_Mod_NV_Status 22 }