Operating instructions
Appendix B RCS20 M:N Redundancy Switch
B-4 TM056 – Rev. 2.3
"Selects internal or external reference clock"
::= { radSNMP_Mod_NV_Status 12 }
radExternalReference OBJECT-TYPE
SYNTAX INTEGER (1000000..10000000)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the external reference frequency in 8 KHz steps."
::= { radSNMP_Mod_NV_Status 13 }
radInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
none(10),
directv(11),
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the various interface types.
The following choices are not supported:
none(10),
Note: Selecting interface types Parallel DVB, Parallel M2P, Serial
DirecTv or HSSI will force the outclock selection to SCT. Selecting
interface type ASI Norm or ASI Null causes the outclock selection to
be forced to None.
"
::= { radSNMP_Mod_NV_Status 14 }
radClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
inverted(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects clock polarity for Tx terrestrial clock relative to Tx data."
::= { radSNMP_Mod_NV_Status 15 }
radDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
inverted(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects data polarity"
::= { radSNMP_Mod_NV_Status 16}
radSpectrum OBJECT-TYPE
SYNTAX INTEGER {
inverted(0),
normal(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Inverts the symbol mapping direction of rotation."