Operating instructions
RCS20 M:N Redundancy Switch Appendix B
TM056 – Rev. 2.3 B-3
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects Tx code rate and type.
Note: Changing the convolutional encoder will affect symbol rate and
data rate. See note at the end of this section.
Unsupported choices include:
none
viterbi6_7
"
::= { radSNMP_Mod_NV_Status 8 }
radClockControl OBJECT-TYPE
SYNTAX INTEGER {
scte(0),
sct(1),
none(2),
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects Tx clock source. 0 selects terrestrial clock
(SCTE), 1 selects internal clock (SCT). Modulators using ASI or G.703
interface options must use SCTE at all times."
::= { radSNMP_Mod_NV_Status 9 }
radFramingMode OBJECT-TYPE
SYNTAX INTEGER {
framing_DirecTv (4)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the frame transport stream input type.
Note: Changing the framing mode will affect the symbol rate and/or data
rate. See note at the end of this section."
::= { radSNMP_Mod_NV_Status 10 }
radRolloff OBJECT-TYPE
SYNTAX INTEGER {
rolloff_0_35 (0),
rolloff_0_2 (1),
rolloff_0_25 (25)
}
ACCESS read-write
STATUS current
DESCRIPTION
"0 selects alpha factor rolloff of 0.35,
'1' selects alpha factor rolloff of 0.2,
'25' selects alpha factor rolloff of 0.25"
::= { radSNMP_Mod_NV_Status 11}
radFreqReferenceSource OBJECT-TYPE
SYNTAX INTEGER {
internal(0),
external(1)
}
ACCESS read-write
STATUS current
DESCRIPTION