Operating instructions

Appendix B RCS20 M:N Redundancy Switch
B-2 TM056 Rev. 2.3
There is an implied decimal point. For example, a value
of 39 represents a transmit power level of +3.9 dBm."
::= { radSNMP_Mod_NV_Status 2 }
radIFFrequency OBJECT-TYPE
SYNTAX INTEGER (50000000..180000000)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects IF frequency in Hz."
::= { radSNMP_Mod_NV_Status 3 }
radDataRate OBJECT-TYPE
SYNTAX INTEGER (0..238000000)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the data rate in bps. Note: Changing data rate will
affect symbol rate, see comment at the end of mibtext."
::= { radSNMP_Mod_NV_Status 4 }
radSymbolRate OBJECT-TYPE
SYNTAX INTEGER (0..68000000)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the symbol rate in sps."
::= { radSNMP_Mod_NV_Status 5 }
radSymbolRateMode OBJECT-TYPE
SYNTAX INTEGER {
variable(0),
fixed(1)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Selects symbol rate mode. This can only be modified if the factory
configuration is set to both variable and fixed.
This is obsolete."
::= { radSNMP_Mod_NV_Status 6 }
radStrapCode OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS optional
DESCRIPTION
"The strap code is a quick set key that sets many modem parameters.
Not implemented."
::= { radSNMP_Mod_NV_Status 7 }
radConvolutionalEncoder OBJECT-TYPE
SYNTAX INTEGER {
none(0),
viterbi1_2(1),
viterbi2_3(2),
viterbi3_4(3),
viterbi5_6(4),
viterbi7_8(5),
viterbi6_7(6),
viterbi8_9(7),