Operating instructions

RCS20 M:N Redundancy Switch Appendix B
TM056 Rev. 2.3 B-1
Appendix B SNMP MIB
-- ___________________________________________________________________________
-- $RCSfile: hsmmib.txt $
-- $Revision: 1.8 $
-- $Date: 2001/06/06 13:56:23 $
-- $Author: edarosa $
--
-- Module Organization :
-- This is a PRILIMINARY document whose contents are subject to change
-- without prior notice.
-- Radyne user MIB Object Identifiers description. The private enterprise
-- number 2591 is a unique identifier assigned to Radyne by the Internet
-- Assigned Numbers Authority (IANA). This number is used to uniquely
-- define vendor specific information such as private MIBs.
--
-- Program Units : (list of program units)
--
-- Requirements Trace : (document(s) and paragraph reference)
--
-- Deviations : (any deviations from the coding standard)
--
-- Revision History : adapted from 3030/3030L usermib
-- ___________________________________________________________________________
RADYNE-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212;
-- groups in Radyne specific MIB
radyne OBJECT IDENTIFIER ::= { enterprises 2591 }
dvb3030 OBJECT IDENTIFIER ::= { radyne 1 }
radSNMP_Mod_NV_Status OBJECT IDENTIFIER ::= { dvb3030 1 }
radSNMP_Mod_Status OBJECT IDENTIFIER ::= { dvb3030 2 }
radCarrierControl OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Turns carrier on and off"
::= { radSNMP_Mod_NV_Status 1 }
radTransmitPower OBJECT-TYPE
SYNTAX INTEGER (-300..50)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the Tx power level in tenths of dBm
from +5.0 to -20.0 (70/140MHz),
from -5.0 to -30.0 (L-Band).