Operating instructions

Electrical Interfaces DVB3030/DVB3030L Digital Video Broadcast Modulator
5-2 TM052 - Rev. 3.5
Table 5-1. J4 (J7 L-Band) - RS-485 Remote Control- 9-Pin ā€˜D’ Female
Pin No. Signal Description Direction
1 Tx (B) Transmit Data (+) Output
5 GND Ground -
6 Tx (A) Transmit Data (-) Output
8 Rx (B) Receive Data (+) Input
9 Rx (A) Receive Data (-) Input
5.5 Terminal Port (I/O)
The Terminal Port Interface (J10 for DVB3030, J5 for DVB3030L) can be used for the monitor &
control functions of the unit. The physical interface is a female 9-Pin D-Sub Connector. This bi-
directional port complies with RS-232 Electrical Specifications. Refer to Section 4.6 for terminal
interface details. The pinouts are listed in Table 5-2.
Table 5-2. J10 (J5 L-Band) - RS-232 Terminal Port - 9-Pin ā€˜D’ Female
Pin No. Signal Name Description Direction
3 TxD Transmit Data Output
2 RxD Receive Data Input
5 GND Ground ---
5.6 Alarm Port
The Alarm Connector (J3 for DVB3030, J6 for DVB3030L) is used to indicate the fault condition
of the modulator to external equipment. This male 9-Pin D-Sub Connector provides connection
to two form-c relays and an open collector output. The user can distinguish between major and
minor alarms with the relays. Refer to Table 5-3 for connector pinouts. Table 5-4 below
describes the alarm indications.
Table 5-3. Alarm Connector J6 Pin Assignment
Pin No. Connection
1
Relay 1 NO
2 Relay 1 C
3 Relay 1 NC (Major Alarm)
4 Ground
5 No Connect
6 Mod Fault (Open Collector)
7 Relay 2 NO
8 Relay 2 C
9 Relay 2 NC (Minor Alarm)