Operating instructions

User Interfaces DVB3030/DVB3030L Digital Video Broadcast Modulator
4-48 TM052 - Rev. 3.5
enterprises.2591.1.2.7.0 = 15 (Revision Number = Version 1.5)
enterprises.2591.1.2.8.0 = 50 (+5V Monitor = + 5 Volts)
enterprises.2591.1.2.9.0 = 122 (+ 12V Monitor = 12.2 Volts)
enterprises.2591.1.2.1 0.0 = -1 20 (-l2V Monitor = -12.0 Volts)
enterprises.2591.1.2.11.0 = 357 (Temperature Monitor = 35.7°C)
END OF MIB
Note: snmpwalk communicates with a host using SNMP GET Next Requests.
4.5 Terminal Port User Interface
The Terminal Port of the DVB3030 allows for complete control and monitoring of all DVB3030
parameters and functions via an RS-232 Serial Interface.
4.5.1 DVB3030 Terminal Mode Control
‘Terminal Mode’ can be entered from the front panel by selecting ‘System’ and then ‘Control
Mode’ followed by ‘Terminal.’ The default settings for the terminal are as follows:
a. 19,200 Baud;
b. 8 Data bits;
c. 1 stop bit;
d. No parity.
The baud rate can be changed at the front panel by using the System>Baud Rate menu.
The new baud rate does not take effect until power to the unit has been shut down and turned
back on again.
4.5.2 Terminal Mode Control Screen Menus
The Terminal Control Mode is menu-driven as shown in the screen captures below. The
allowable values for each item number are shown. To change an item, type in its number
followed by <ENTER>. If the parameter to be changed requires a numeric value, enter the
number followed by <ENTER> If the parameter is non-numeric, press <SPACE> to cycle
through the list of available entries. Note that the items that do not have ID numbers are Status
only and cannot be changed.