Operating instructions

User Interfaces DVB3030/DVB3030L Digital Video Broadcast Modulator
4-16 TM052 - Rev. 3.5
4.2.6 System Options and Parameters Menu
The System Screens are shown in Figure 4-9. These include:
1. General (menu)
Control Mode: {FT Panel, Computer, Terminal}
Enter the control mode for:
FT Panel (Front panel commands accepted), or
Terminal (Terminal commands accepted), or
Computer (Computer M&C commands
accepted).
Address: Multi-Drop Address: Enter the address for
computer control from 32 to 255.
Date: Enter the date in YY/MM/DD format.
Time: Enter the time in HH:MM:SS format.
Bklt Level: {Low, Mid, High, ON}
Enter the backlight level intensity. ‘ON’ will
disable the timeout and backlight will remain on.
Bklt Timeout: Enter the timeout for the backlight in 1 second
intervals from 0 to 99 seconds.
Key Click: {Off, On}
Set Key Click.
Baud Rate: {2400, 9600, 19200}
Remote port baud rate for Terminal and
Computer Mode.
Note: When changing the Baud Rate, power must be cycled for the new rate to take
effect.
Stop Bits (N/A): Number of Stop Bits is always 1 for Remote
Port.
Parity (N/A): Parity is always None for Remote Port.
Terminal Emulation: {ADDS VP, VT100, WYSE 50}
Set Remote Port Terminal Mode Emulation.
Version #.#: Displays software revision number.
INT CPLD: Displays Interface CPLD Revision Number.
INT FPGA: Displays Interface FPGA Revision Number.
Version #.#: Displays Convolutional Encoder Revision
Number