Protection against Lightning Chapter 3
RADWIN 1000/2000 User Manual Version 2.12 3-2
also lays down the size of grounding conductors and connection
requirements for grounding electrodes.
The RADWIN 1000/2000 ODU must be grounded to a Protective
Earth as described in appendix E and in accordance with the Local
Electrical Regulations.
The earth lug on the IDU-C should be connected to the protective
earth at all times, by a wire with a diameter of 18 AWG or wider.
Rack-mounted equipment should be mounted only in earthed racks
and cabinets.
Further, you should -
Always make the ground connection first and disconnect it last
Never connect telecommunication cables to ungrounded equipment
Ensure that all other cables are disconnected before disconnecting
the ground
More detailed guidelines are supplied in appendix E.
Protection against Lightning
The use of lightning protection is dependent on regulatory and end user
requirements. All of RADWIN outdoor units are designed with surge limiting
circuits to minimize the risk of damage due to lightning strikes. RADWIN
recommends the use of additional surge arrestor devices to protect the
equipment from nearby lightning strikes.
See appendix E for detailed installation instructions of lightning protection
devices.
General
It is recommended that installation of the outdoor unit be contracted
to a professional installer.
Before working on equipment connected to power lines or telecom-
munication lines, you should remove jewelry or any other metallic
object that may come into contact with energized parts.
Use extreme care when installing antennas near power lines.
Use extreme care when working at heights.
When using an AC power source for RADWIN 1000/2000 always use
the AC power adapter supplied by RADWIN.
Use the right tools. In addition to standard tools required for any
kind of ODU or antenna installation, RADWIN 1000/2000 requires
additional specific tools detailed on page 3-5 below.
Package Contents
The RADWIN 1000/2000 packages include the following items:
ODU Package Contents
The ODU package contains: