User's Manual Part 2

Outdoor Connections Chapter 3
RADWIN 1000/2000 User Manual Version 2.2a 3-8
recommends the use of additional surge arrestor devices to protect the
equipment from nearby lightning strikes.
Refer to appendix E for detailed installation instructions of lightning protec-
tion devices.
Outdoor Connections
¾ To complete the outdoor connections:
1. Connect the ground cable to the ODU chassis as marked on the ODU.
2. Connect the antenna cable(s) to the ODU.
3. Connect the lightning protection device to the ODU (see appendix E).
4. Attach the ODU-IDU cable to the ODU RJ-45 connector (see appendix B
for the connector pin-out)
5. Screw in the cable glands to ensure hermetic sealing of the ODU.
6. Secure the cables to the pole, mast or brackets using UV-rated cable ties.
Indoor Installation
Mounting the IDUs
The RADWIN 1000/2000 IDUs are all rack mounted, as shown in figure 1-
6. A front panel keyed schematic of a rack mounted IDU-C is shown in
figure 3-7 below.
Figure 3-7: IDU-C front panel
In figure 3-8 we display a perspective view of the IDU-C: