Installation Guide
Table Of Contents
- Table of Contents
- Chapter 1: Introduction
- Chapter 2: Installation Steps
- 2.1 Prepare Laptop
- 2.2 Connect Laptop to Radio Unit
- 2.3 Update Connectivity Parameters of Radio Unit
- 2.4 Check items to be installed
- 2.5 Prepare Tools
- 2.6 Install Standard Mounting Kit
- 2.7 Install Mounting Kit for the SU PRO/AIR EMB
- 2.8 Mounting a Unit with the Standard Mounting Kit
- 2.9 Ground Radio Unit
- 2.10 Mounting the SU PRO/AIR EMB
- 2.11 Mounting the SU PRO/AIR INT
- 2.12 Mounting the Lightning Protection Units
- 2.13 Connect External Antenna (if applicable)
- 2.14 Waterproofing
- 2.15 Connect Radio (External Connections)
- 2.16 Check Connectivity to Radio
- 2.17 Activate Base Station
- 2.18 Align Subscriber Unit
- Chapter 3: Safety Practices and Provisions
- Appendix A: Wiring Specifications
- Appendix B: About Antennas
- Appendix C: Regional Notice: French Canadian
- Appendix A: Terminology
- Appendix E: Revision History
- Appendix F: Certified Antennas
- RADWIN Worldwide Offices
RADWIN5000InstallationGuideDQ0266610/A.01 F‐1
AppendixF:CertifiedAntennas
F.1ForDeploymentinUS/Canada
RadiodevicesthatbearthefollowingFCC/ICIDsrefertoTable F‐1toTable F‐4below:
ContainsFCCID:Q3K‐5XACMOLD
ContainsIC:5100A‐5XACMOD
Onlytheantennasshowninthetablesbeloworantennasofthesametypewithlowergain
areapprovedforuseinthissystem.Theantennasmustbeinstalledsoastoprovidea
minimumseparationdistancefrombystandersasspecifiedinthetablesbelow:
TableF‐1:FrequencyBand5725‐5850MHz
Cat.No. Type Gain(dBi)
Dir
BW
TxPower
perchain
(dBm)
Min.Safe
Distance(cm)
Integrated FlatDPBS 11.0 120° 25 26
RW ‐9061‐5004 FlatDPBS 11.0 120° 25 26
Integrated FlatDPBS 12.0 95° 25 29
Integrated FlatDPBS 13.0 90° 25 32
RW ‐9061‐5001 FlatDPBS 14.0 90° 25 36
RW ‐9061‐5002 FlatDPBS 15.5 60° 25 43
Integrated FlatDP 16.0 35° 25 45
Integrated FlatDP 16.5 35° 25 48
RW ‐9613‐4960 FlatDP 23.0 8° 25 100
Integrated FlatDP 23.5 8° 25 107
RW ‐9622‐5001 FlatDP 29.0 5° 25 200
RW ‐9401‐5002 SharkFinSP 12.5 50° 25 30