Installation Guide
Table Of Contents
- Table of Contents
- Chapter 1: Introduction
- Chapter 2: Installation Steps
- 2.1 Prepare Laptop
- 2.2 Connect Laptop to Radio Unit
- 2.3 Update Connectivity Parameters of Radio Unit
- 2.4 Check items to be installed
- 2.5 Prepare Tools
- 2.6 Install Standard Mounting Kit
- 2.7 Install Mounting Kit for the SU PRO/AIR EMB
- 2.8 Mounting a Unit with the Standard Mounting Kit
- 2.9 Ground Radio Unit
- 2.10 Mounting the SU PRO/AIR EMB
- 2.11 Mounting the SU PRO/AIR INT
- 2.12 Mounting the Lightning Protection Units
- 2.13 Connect External Antenna (if applicable)
- 2.14 Waterproofing
- 2.15 Connect Radio (External Connections)
- 2.16 Check Connectivity to Radio
- 2.17 Activate Base Station
- 2.18 Align Subscriber Unit
- Chapter 3: Safety Practices and Provisions
- Appendix A: Wiring Specifications
- Appendix B: About Antennas
- Appendix C: Regional Notice: French Canadian
- Appendix A: Terminology
- Appendix E: Revision History
- Appendix F: Certified Antennas
- RADWIN Worldwide Offices
RADWIN5000InstallationGuide DQ0266610/A.01 2‐44
SUPRO/AIREMBUnits InstallationSteps
Figure2‐52:IDU‐Hpowerconnectorsandgroundinglug.
• FordirectDCconnection:Theconnectorsare3pininlinefemale,withpolarities(leftto
right)minus,ground,plus,asshown:
• ForACconnection:ToavoiddamagetotheIDU‐H,alwaysusetheAC/DCadapterand
powerplugsuppliedbyRADWIN.
2.15.3SUPRO/AIREMBUnits
1. ConnectaCAT‐5ecabletotheinputportoftheradioasshown:
UseonlyasafetyapprovedIDU‐HaccordingtoIEC/EN/UL60950‐1or
62368‐1withratedoutputvoltageof46‐55VDCandratedcurrentof4A
max.
Groundtheunitwitha10AWGwirebeforeapplyingpower.
Figure2‐53:Inputport:SUPRO/AIREMB
unit
Minus PlusGround
InsertRJ45
cable