Maximum Output Power
3650 – 3700 MHz band - FCC/IC
The maximum EIRP must be set as follows, when operating in the 3.65 - 3.70 GHz band,
under FCC and IC regulations.
2x2 Configuration
3x3 Configuration
Radiation Exposure Evaluation
RADWIN 2000 JET and RADWIN 5000 3.x GHz systems - the calculated recommended safe
distance at density of 1mW/cm
2
is 53.6cm.
RADWIN 2000 JET, RADWIN 5000 JET 3.x GHz Reference Guide 2
Channel BW
(MHz)
Center Freq. Range
(MHz)
Max EIRP
(dBm)
5
3652.5 – 3697
35.0
10
3655 – 3695
38.0
20
3661 – 3689
42.0
40
3675
43.0
Channel BW
(MHz)
Center Freq. Range
(MHz)
Max EIRP
(dBm)
5
3652.5 – 3697
36.0
10
3655 – 3695
39.0
20
3661 – 3689
42.0
40
3675
43.0