Chapter 5 Diagnostics and Troubleshooting WinLink 1000 Installation and Operation Manual
5-6 Troubleshooting
Tes ti ng
Equipment
Management
Station
E1
Interface
/T1 E1
Interface
/T1
Local ODU
Inband Loopback
Activation Command
Remote ODU
Figure
5-5. Remote External Loopback
Local Internal Loopback
Local WinLink 1000 can be set to close an internal loopback to test
connection between the local and remote units, remote E1/T1 port and
its connection to the remote side user equipment. In this mode, data
coming from the remote user equipment is looped back to it (see
Figure
5-6
). This loopback is initiated by an inband command sent
from a management station connected to the local unit.
Tes ti ng
Equipment
Management
Station
Local ODU
Inband Loopback
Activation Command
Remote ODU
E1/T1
Interface
E1
Interface
/T1
Figure
5-6. Local Internal Loopback
5.4 Troubleshooting
The WinLink 1000 LEDs show faults in the system or the link. Use
Table 5-2 to diagnose the fault.