User's Manual

WinLink User and Installation Guide Version 1.770 K-184
Name
OID
Type
Access
Description
winlink1000IduSrvEthThroughput
1.3.6.1.4.1.4458.1000.2.2.14 Gauge RO Current available Ethernet service throughput in
bps.
winlink1000IduSrvEthMaxInfoRate
1.3.6.1.4.1.4458.1000.2.2.15 Integer RW
Holds the maximum bandwidth (kbps) to be
allocated for ethernet service. Value of zero
means that ethernet service works as best effort.
The maximum value is product specific
winlink1000IduEthernetIfTable
N/A
IDU Ethernet Interfaces Table.
winlink1000IduEthernetIfEntry
N/A
Table entry. INDEX {
winlink1000IduEthernetIfIndex }
winlink1000IduEthernetIfIndex
RO If Index corresponding to this Interface.
winlink1000IduEthernetIfAddress
1.3.6.1.4.1.4458.1000.2.3.1.1.5 DisplayString RO IDU MAC address.
winlink1000IduEthernetNumOfLanPorts
1.3.6.1.4.1.4458.1000.2.3.3 Integer RO The number of LAN interfaces in the IDU.
winlink1000IduBridgeTpAging
1.3.6.1.4.1.4458.1000.2.4.4.2 Integer RW
Timeout in seconds for aging. Note that in order
for this parameter to be effective
winlink1000IduTdmTxClockAvailStates
1.3.6.1.4.1.4458.1000.2.6.1.1 Integer RO The available states of the TDM Tx Clock Control
winlink1000IduTdmTxClockDesiredState
1.3.6.1.4.1.4458.1000.2.6.1.2 Integer RW
The desired state of the TDM Tx Clock Control. A
change is effective after re-activation of the TDM
service.
winlink1000IduTdmTxClockActualState
1.3.6.1.4.1.4458.1000.2.6.1.3 Integer RO The actual state of the TDM Tx Clock Control.
winlink1000IduTdmMasterClockAvailOpt
ions
1.3.6.1.4.1.4458.1000.2.6.2.1 Integer RO The available options of the TDM Master Clock
Control
winlink1000IduTdmMasterClockDesired
1.3.6.1.4.1.4458.1000.2.6.2.2 Integer RW
The desired TDM Master Clock. A change is
effective after re-activation of the TDM service.
winlink1000IduTdmMasterClockActual
1.3.6.1.4.1.4458.1000.2.6.2.3 Integer RO The actual Trunk used for TDM Master Clock.
winlink1000IduTdmConfigTable
N/A
IDU TDM Links Configuration Table.
winlink1000IduTdmConfigEntry
N/A
Table entry. INDEX {
winlink1000IduTdmConfigIndex }
winlink1000IduTdmConfigIndex
RO Table index.
winlink1000IduTdmIfIndex
RO Link index in the interfaces table.
winlink1000IduTdmLineCoding
1.3.6.1.4.1.4458.1000.2.6.6.1.6 Integer RW
This parameter applies to T1 trunks only. The
parameter controls the line coding. Setting the
value to each of the indices applies to all.A
change is effective only after the next open of the
TDM service.
winlink1000IduTdmLoopbackConfig
1.3.6.1.4.1.4458.1000.2.6.6.1.9 Integer RW
Loop back configuration table. Each of the trunks
can be set Normal
winlink1000IduTdmLineStatus
1.3.6.1.4.1.4458.1000.2.6.6.1.10 Integer RO Line status.