User's Manual

WinLink User and Installation Guide Version 1.770 K-181
Name
OID
Type
Access
Description
winlink1000OduPerfMonTdmCurrEntry
N/A
This is an entry in the Current Interval Table.
INDEX {ifIndex }
winlink1000OduPerfMonTdmCurrActive
Seconds
1.3.6.1.4.1.4458.1000.1.6.10.1.1 Gauge RO The parameter indicates whether the TDM service
was active. Under TDM backup link
winlink1000OduPerfMonTdmIntervalTab
le
N/A
This table defines/keeps the counters of the
current 15 min interval.
winlink1000OduPerfMonTdmIntervalEntr
y
N/A
This is an entry in the Interval Table. INDEX
{ifIndex
winlink1000OduPerfMonTdmIntervalIdx
RO This table is indexed per interval number. Each
intervalis of 15 minutes and the oldest is 96.
winlink1000OduPerfMonTdmIntervalActi
veSeconds
RO The parameter indicates whether the TDM service
was active. Under TDM backup link
winlink1000OduPerfMonTdmDayTable
N/A
This table defines/keeps the counters of the
current 15 min interval.
winlink1000OduPerfMonTdmDayEntry
N/A
This is an entry in the Days Table. INDEX {ifIndex
winlink1000OduPerfMonTdmDayIdx
RO This table is indexed per Day number. Each Dayis
of 15 minutes and the oldest is 96.
winlink1000OduPerfMonTdmDayActive
Seconds
RO The parameter indicates whether the TDM service
was active. Under TDM backup link
winlink1000OduPerfMonTxThresh1
1.3.6.1.4.1.4458.1000.1.6.20 Integer RW
When the TX power exceeds this threshold
winlink1000OduPerfMonRxThresh1
1.3.6.1.4.1.4458.1000.1.6.21 Integer RW
When the RX power exceeds this threshold
winlink1000OduPerfMonRxThresh2
1.3.6.1.4.1.4458.1000.1.6.22 Integer RW
When the RX power exceeds this threshold
winlink1000OduPerfMonBBERThresh1
1.3.6.1.4.1.4458.1000.1.6.23 Integer RW
When the BBER exceeds this threshold
winlink1000OduAgnGenAddTrapExt
1.3.6.1.4.1.4458.1000.1.7.1.1 Integer RW
If 'yes' is chosen
winlink1000OduAgnNTPCfgTimeServerI
P
1.3.6.1.4.1.4458.1000.1.7.2.1 IpAddress RW
The IP address of the server from which the
current time is loaded.
winlink1000OduAgnNTPCfgTimeOffsetF
romUTC
1.3.6.1.4.1.4458.1000.1.7.2.2 Integer RW
The offset from Coordinated Universal Time
(minutes). Possible values: -1440...1440.
winlink1000OduAgnRealTimeAndDate
1.3.6.1.4.1.4458.1000.1.7.2.3 OctetString RW
This parameter specifies the real time and date
Format 'YYYY-MM-DD
winlink1000OduAgnCurrAlarmLastChan
ge
1.3.6.1.4.1.4458.1000.1.7.3.1 Integer RO This counter is initialized to 0 after a device reset
and is incremented upon each change in the
winlink1000OduAgnCurrAlarmTable(either an
addition or removal of an entry).
winlink1000OduAgnCurrAlarmTable
N/A
This table includes the currently active
alarms. When a RAISED trap is sent