Name
OID
Type
Access
Description
winlink1000OduReadWriteCommunity
1.3.6.1.4.1.4458.1000.1.1.16 DisplayString RW
The Read/Write Community String. This variable
always returns ***** when retrieving its value. It is
used by the element manager to change the
Read/Write Community String. The SNMP agent
accepts only encrypted values.
winlink1000OduTrapCommunity
1.3.6.1.4.1.4458.1000.1.1.17 DisplayString RW
The Trap Community String. This variable is used
by the element manager to change the Trap
Community String. The SNMP agent accepts only
encrypted values.
winlink1000OduAdmSnmpAgentVersion
1.3.6.1.4.1.4458.1000.1.1.18 Integer RO Major version of the SNMP agent.
winlink1000OduAdmRemoteSiteName
1.3.6.1.4.1.4458.1000.1.1.19 DisplayString RO Remote site name. Returns the same value as the
sysLocation variable of the remote site would.
winlink1000OduAdmSnmpAgentMinorV
ersion
1.3.6.1.4.1.4458.1000.1.1.20 Integer RO Minor version of the SNMP agent.
winlink1000OduAdmLinkPassword
1.3.6.1.4.1.4458.1000.1.1.21 DisplayString RW
Link Password. This variable always returns *****
when retrieving its value. It is used by the element
manager to change the Link Password. The
SNMP agent accepts only encrypted values.
winlink1000OduAdmSiteLinkPassword
1.3.6.1.4.1.4458.1000.1.1.22 DisplayString RW
Site Link Password. This variable always returns
***** when retrieving its value. It is used by the
element manager to change the Link Password of
a single site. The SNMP agent accepts only
encrypted values.
winlink1000OduAdmDefaultPassword
1.3.6.1.4.1.4458.1000.1.1.23 Integer RO This parameter indicates if the current Link
Password is the default password.
winlink1000OduAdmConnectionType
1.3.6.1.4.1.4458.1000.1.1.24 Integer RO This parameter indicates if the Manager
application is connected to the local ODU or to the
remote ODU over the AIR interface
winlink1000OduAdmBackToFactorySetti
ngsCmd
1.3.6.1.4.1.4458.1000.1.1.25 Integer RW
Back to factory settings Command. A change is
effective only after reset. The read value is always
0.
winlink1000OduAdmIpParamsCnfg
1.3.6.1.4.1.4458.1000.1.1.26 DisplayString RW
ODU IP Configuration. The format is as follows:
%IP_ADDR%|%NET_MASK%|%GATEWAY%|
winlink1000OduAdmVlanID
1.3.6.1.4.1.4458.1000.1.1.27 Integer RW
This is the ID of the VLAN. Valid ID is from 1 to
4094.This ID is initialized to 0 which means that
no-VLAN is installed.
winlink1000OduAdmVlanPriority
1.3.6.1.4.1.4458.1000.1.1.28 Integer RW
This is the priority of the VLAN. 0 is the lowest
priority
winlink1000OduSrvMode
1.3.6.1.4.1.4458.1000.1.2.1 Integer RW
Administrative mode of the system. The only
mode that can be set is installMode
winlink1000OduSrvBridging
1.3.6.1.4.1.4458.1000.1.2.3 Integer RO Bridging Service Admin Mode. The valid values
are: disabled (0)
winlink1000OduEthernetRemainingRate
1.3.6.1.4.1.4458.1000.1.3.1 Integer RO Current Ethernet bandwidth in bps.